https://www.avient.com/sites/default/files/2025-02/Hexagon and digimat case study.pdf
The resulting tensile test
data shown in Figure 1 gives an indication of the variation
in material response that can be observed as a function of
the fibre orientations.
In reality, the material response can
fall anywhere between the curves shown in Figure 1.
Figure 1: Tensile test data as a function of the fibre orientation 0°
(orange), 45° (green), 90° (blue)
https://www.hexagonmi.com
Figure 4: Failure location in the flexural test for the isotropic modelling
Figure 6: Failure location in the tensile test for the isotropic modelling
approach (left), Digimat anisotropic modelling approach (middle) and
reality (right)
Figure 3: Flexural test results with the isotropic modelling approach
(orange) and Digimat anisotropic modelling approach (green)
Figure 5: Tensile test results with the isotropic modelling approach
(orange) and Digimat anisotropic modelling approach (green)
Figure 5 shows the tensile test results with, again,
a convincing advantage for the Digimat anisotropic
modelling approach against the isotropic modelling
approach.
https://www.avient.com/sites/default/files/2023-10/2023 Syncure Wire and Cable Product Selection Guide.pdf
Syncure™ XLPE
Cross-linkable
Polyethylene
Formulations
FOR LOW VOLTAGE CABLES
PRODUCT SELECTION GUIDE
Syncure™ XLPE
MOISTURE CROSS-LINKABLE POLYETHYLENE INSULATION FOR LOW VOLTAGE CABLE SYSTEMS
SYSTEM S100FH S100FH-XUV S100FH-UV S100FV S100FV-UV S112NA S120NA S200FH S200FV
Applications
Building Wire,
Tray Cable
Building Wire,
Tray Cable
Photo-Voltaic (PV)
Wire
Building Wire,
Tray Cable
Building Wire,
Tray Cable
Building Wire,
Teck-90
Pipe and Tube
Building Wire, Tray Cable,
Service Entrance
Building Wire, Tray Cable,
Service Entrance
Specification UL 44 UL 44 UL 44, UL 4703 UL 44 UL 44 CSA 22.2
Suitable for
NSF 61
UL 44 UL 44
Wire Type
XHHW-2, RHW-2, USE-2,
SIS
XHHW-2, RHW-2, USE-2,
SIS
XHHW-2, RHW-2,
USE-2, SIS, PV
XHHW-2, RHW-2,
SIS
XHHW-2, RHW-2,
USE-2, SIS, PV
RW-90, Teck-90 –
RHW-2, RHW, RHH,
XHHW-2, XHH, XHHW, SIS
RHW, RHH, RHW-2
Components %
83% S1054A
17% V0022G RoHS
83% S1054A
17% V0022G-UV RoHS
70% S1054A
30% V0022G-UV RoHS
50% S1054A
50% V0044G RoHS
50% S1054A
50% V0044G-UV RoHS
95% S1054A
5% S1000B
95% S1016A
5% S1037B
78% S1054A
22% SC5400-0002 RoHS
MB ALT FR
50% S1054A
50% SC5400-0003 RoHS
MB ALT FR
Features
Horizontal
Flame
Horizontal Flame,
UV Resistant,
Colors Possible
Horizontal Flame,
FV-1 Flame, UV Resistant,
Colors Possible
VW-1
VW-1, UV Resistant,
Colors Possible
Non-FR Rigid Pipe Applications
Horizontal Flame,
DBDPE-free
VW-1, DBDPE-free
GENERAL PROPERTIES
Specific Gravity 1.01 1.02 1.10 1.31 1.31 0.92 0.95 1.01 1.31
Hardness Shore D,
10 Seconds
47 47 47 48 48 47 59 47 48
Gel 68 68 70 70 70 72 72 68 70
TENSILE PROPERTIES
Tensile Strength
(psi) 2800 2500 2650 3200 2650 2800 4500 2800 3200
Elongation % 400 400 540 470 540 400 80 400 470
Tensile
Retention %
100 100 97 110 110 95 75 95 100
Elongation
Retention %
90 90 94 100 100 90 75 90 93
ELECTRICAL
Dielectric
Strength (V/mil) 1000 1400 1400 1200 1200 1000 – 1000 1200
Dielectric
Constant
2.31 2.45 2.61 2.61 2.61 2.24 2.1 2.31 2.61
Dissipation
Factor %
0.0012 0.0080 0.008 0.0043 0.0043 0.0008 0.002 0.0012 0.0043
THERMAL
Temperature
Rating °C
90 90 90 90 90 90 125 90 90
Heat
Deformation %
10 5 5 5 5 10 10 10 5
The Syncure™ XLPE portfolio is a two-step, silane-
grafted, moisture cross-linkable polyethylene system.
https://www.avient.com/sites/default/files/2020-12/firecon-cpe-a-processing-guide.pdf
EXTRUDER
Screw 1" to 6" deep flighted metering screw 3:1 compression ratio
Tooling
Tubing type – zero land (for smaller sizes)
Pressure type – for 1" size or larger
Die
Tubing type – low DDR
Pressure type – short land
L/D 24:1 or higher
Screen Pack 20/40/20 Mesh
Cooling Trough 120–150 °F (50–65 °C) recommended
Dryer Hot air or desiccant type, 4 hours at 175–185 °F
PROCESSING
Temperature
Wire Preheat None
Feed Zones 290–300 °F
Transition 320–340 °F
Metering 340–350 °F
Head/Die 350–365 °F
Target Melt 350–365 °F
Maximum Melt 390 °F
Purge Compound HDPE
www.avient.com
Copyright © 2020, Avient Corporation.
https://www.avient.com/sites/default/files/2020-09/versaflex-pf-final.pdf
VersaflexTM PF
Versaflex PF
VOC
Versaflex PF
VERSAFLEX PF
VOC
39 LDPE / 13 Versaflex PF
VERSAFLEX PF
39 LDPE / 13 Versaflex PF
N
/
2
5
m
m
N
/
2
5
m
m
F = 25 ° C 7 I = 25 ° C 20
MD6741 / MD6700
VERSAFLEX PF
TM
+86 021 60284888
www.avient.com
VERSAFLEX™ PF
1 CF6751 PP
2 2420K LDPE
Versaflex™ PF
MD6727
Versaflex™ PF
MD6741
Versaflex™ CF
6751
Versaflex™ PF
MD6649
Versaflex™ PF
9512
Versaflex™ CF
8888N-A
Versaflex™ PF
MD6666
Versaflex™ PF
MD6748
Versaflex™ PF
MD6700
Versaflex™ CF
9000
PP
PVC
Tg (°C) -26 -43 -30 -26 -5 1 -6 0 5 /
(Shore A) 50 49 35 37 38 35 37 31 30 19
MFI (190°C, 2.16kg)
(g/10min)
/ / / 15 5 15 20 3 5 27
MFI (230°C, 2.16kg) 8 20 8 / / / / / / /
1 LDPE 2420k2/LDPE 2420k/Versaflex™ =4.5/4.5/1 ; =50um
(N/25mm)
25°C 20 1.3 1.8 7.9 2.5 2.2 2.7 3.3 3.0 3.7 4.3
75°C 7 5.7 2.9 7.2 3.1 4.0 4.3 4.3 5.5 5.6 /
PMMA
(N/25mm)
25°C 20 1.8 2.0 7.2 2.6 2.8 3.0 3.6 3.3 3.9 4.9
75°C 7 5.5 4.7 7.1 3.5 / 4.7 6.5 5.8 6.9 /
https://www.avient.com/sites/default/files/2021-05/avient-responsible-care-ehs-s-policies-2021.pdf
Bob Patterson
Chairman, President, and CEO
August 1, 2020
SAFETY & HEALTH POLICY
Avient Corporation believes safety and health are the highest corporate
priority.
Bob Patterson
Chairman, President, and CEO
August 1, 2020
Product Stewardship Policy
Product Stewardship plays a significant role in Avient’s sustainable and
ethical business practices.
Bob Patterson
Chairman, President, and CEO
August 1, 2020
https://www.avient.com/sites/default/files/2020-08/2020-hammerhead-application-install-guide.pdf
MARINE PLYWOOD
Hammerhead™ panels are three times lighter than marine plywood
MOISTURE ABSORPTION % weight change due to water absorption for selected composites and marine plywood
10000
60000
110000
160000
210000
260000
310000
360000
0.5 0.75 1 1.25 1.5
F
le
x
u
ra
l
R
ig
id
it
y
-
lb
/
in
2
Panel Thickness - in
Hammerhead™ 5.3lb/in^3 Core Density Hammerhead™ 8.4lb/in^3 Core Density Plywood
— Hammerhead™ 5.3 lb/ft3 Core Density
— Hammerhead™ 8.4 lb/ft3 Core Density
— Marine Plywood
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
0 10 20 30 40 50 60 70 80 90 100
%
W
e
ig
h
t
C
h
a
n
g
e
Immersion Time - Days
.50" Hammerhead™ .75" Hammerhead™ 1" Hammerhead™ 1.50" Hammerhead™
.50" marine plywood .75" marine plywood 1" marine plywood
Fl
ex
ur
al
R
ig
id
it
y
- l
b-
in
2
INSTALLATION INSTRUCTIONS
CUTTING & DRILLING
Recommended blade: Industrial fine cut-off saw blade, 10" x 80 teeth 38° ATB grind with 5/8" bore,
PTFE coating
Recommended router bits: 3/8" diameter, 4 flute TiAlN (titanium aluminum nitride) coated carbide bit
FORMING
Apply localized 400˚F heat at a length proportional to the panel thickness (see equation below)
and bend to shape.
Heat Length =
π
2 * Thickness
Radius = S
B
S
T = 400°F
B S
G
LA
SS
/E
P
O
XY
T
AB
M
AT
ER
IA
L
TAB TESTING OF VARIOUS INSTALLATION METHODS
Hammerhead™
PETG Laminate
Hammerhead™
PETG Laminate
BOTTOM PANEL
LEG
LENGTH
BREAK
STRENGTH (LBS)
PETG Skins
with Plywood Core
1 in
1.5 in
2 in
2400
2820
2748
Hammerhead™
with 5.3 lb/ft3
Core Density
2 in 665
Hammerhead™
with 8.4 lb/ft3
Core Density
2 in 1084
Marine Plywood 2 in 770
Glass/Epoxy with
Plywood Core 2 in 1055
Glass/Polyester
with Balsa Core 2 in 919
L-Bracket Installation
Hammerhead™
PETG Laminate
Hammerhead™
PETG Laminate
BOTTOM PANEL
LEG
LENGTH
BREAK
STRENGTH (LBS)
PETG Skins
with Plywood Core 2 in 2375
Marine Plywood 2 in 770
Glass/Polyester
with Balsa Core 2 in 797
U-Channel Installation
N
O
T
AB
BOTTOM PANEL
LEG
LENGTH
BREAK STRENGTH
(LBS)
Hammerhead™
with 5.3 lb/ft3
Core Density
2 in 420
Hammerhead™
with 8.4 lb/ft3
Core Density
2 in 332
Marine Plywood 2 in 984
Glass/Polyester with
Balsa Core 2 in 1298
Hammerhead™
with 5.3 lb/ft3
Core Density -
ITW Plexus
MA420 Adhesive
NA 501
Hammerhead™
with 8.4 lb/ft3
Core Density -
ITW Plexus
MA420 Adhesive
NA 1156
Hammerhead™
with 8.4 lb/ft3
Core Density -
Crestomer
1152PA Adhesive
NA 1530
Hammerhead™
with 8.4 lb/in3
Core Density -
Crestomer
M1-30 Adhesive
NA 1471
Mixed Conditions
ITW Plexus MA420 adhesive was used in all tab
testing installations except where noted.
BOTTOM PANEL
LEG
LENGTH
BREAK STRENGTH
(LBS)
Hammerhead™
with 5.3 lb/ft3
Core Density
2 in 420
Hammerhead™
with 8.4 lb/ft3
Core Density
2 in 332
Marine Plywood 2 in 984
Glass/Polyester with
Balsa Core 2 in 1298
Hammerhead™
with 5.3 lb/ft3
Core Density -
ITW Plexus
MA420 Adhesive
NA 501
Hammerhead™
with 8.4 lb/ft3
Core Density -
ITW Plexus
MA420 Adhesive
NA 1156
Hammerhead™
with 8.4 lb/ft3
Core Density -
Crestomer
1152PA Adhesive
NA 1530
Hammerhead™
with 8.4 lb/in3
Core Density -
Crestomer
M1-30 Adhesive
NA 1471
ADHESIVE
DESCRIPTION
ADHESIVE
GRADE
MANUFACTURER
AVERAGE
BOND
STRENGTH
(PSI)
STANDARD
DEVIATION
FAILURE
MODE
BEST ADHESION
2k Urethane 75421 Lord 2281 184 SubstrateCohesive
2k Acrylic SA1-705 GRY1 AccraLock 2211 78 Substrate
2k Acrylic Plexus MA420 ITW 2171 262 Substrate
2k Acrylic SA10-05 Blk1 AccraLock 2102 138 Substrate
2k Urethane 75451 Lord 2047 68 Cohesive
2k Acrylic SA1-705 GRY 1:2 AccraLock 1966 68 Substrate
2k Acrylic Scotchweld 8010 3M 1907 61 Adhesive
Cyanoacrylate Gorilla Glue Gorilla Glue 1885 432 Cohesive
2k Acrylic Crestabond PP-04 Scott Bader 1873 281 Substrate
2k Acrylic SA10-05 Blk 10:2 AccraLock 1779 127 Cohesive
2k Urethane 75422 Lord 1716 190 CohesiveAdhesive
2k Urethane 75452 Lord 1535 98 Adhesive
2k Methacrylate Polyfuse Icon Containment 1610 98 Adhesive
INTERMEDIATE ADHESION
2k Acrylic FA10-05 Blk C010817 AccraLock 724 58 Cohesive
2k Acrylic FA10-05 Blk1 AccraLock 722 44 Cohesive
2k Epoxy Loctite Epoxy Instant Mix Loctite 508 81 Adhesive
2k Epoxy Gorilla Glue Epoxy Gorilla Glue 341 198 Adhesive
NOT RECOMMENDED
2k Epoxy Loctite Epoxy Marine Loctite 0 0 No bond
ADHESIVE SELECTION
Brands identified are owned by the manufacturers of the adhesive products.
1 surface sanded with 220 grit scuff prep 2 surface primed with 459T
FASTENER TYPE BENEFITS CONSIDERATIONS
Through-Bolting
Best mechanical
locking system
Need back side
access to panel
Screw-In Anchor
Highest pullout
strength
Requires pilot hole
Cup Washer
Spreads
compressive load
Requires relief hole;
For substructure and
hard point attachment
Wide Grip
(Bulb-Style)
Rivet
Ease of use—no
installation torque
limitations
For lower
load attachments
Sheet Metal or
Wood Screw
Readily available,
low cost
Penetrate both skins
for improved pullout
Shoulder Washer
Limits
compressive load
Requires relief hole;
For substructure and
hard point attachment
For more information on installation, adhesives, and fasteners
for specific applications, please contact Avient.
https://www.avient.com/sites/default/files/2023-02/turkisk-entity-legal-information-en-tu.pdf
İNTERNET SİTESİ İÇERİĞİ
POLYONE TEKNO POLİMER MÜHENDİSLİK PLASTİKLERİ SANAYİ VE TİCARET
ANONİM ŞİRKETİ
Şirket Bilgileri (Yönlendirilmiş Mesaj)
No İçerik Detay
1 Ticaret Unvanı Polyone Tekno Polimer
Mühendislik Plastikleri Sanayi
ve Ticaret Anonim Şirketi
2 MERSİS Numarası 0836003561100014
3 Merkezi Orhan Gazi Mah.1683 Sk.
No.150
Şişli/İstanbul
1
WEBSITE CONTENT
POLYONE TEKNO POLİMER MÜHENDİSLİK PLASTİKLERİ SANAYİ VE TİCARET
ANONİM ŞİRKETİ
Content to be published permanently
* Please note that in case of any changes to the following content, the update shall be
published on the websites on the date such changes occur.
No Content Detail
1 MERSIS number of the Company 0836003561100014
2 Title of the Company Polyone Tekno Polimer
Mühendislik Plastikleri Sanayi
ve Ticaret Anonim Şirketi
3 Registered office of the Company Orhan Gazi Mah.1683 Sk.
https://www.avient.com/sites/default/files/2024-02/US_OH_North Baltimore_ ISO_IEC 17025.pdf
No. 0562.01) Revised 05/31/2022 Page 1 of 1
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
AVIENT CORPORATION
733 East Water Street
North Baltimore, OH 45872
Claire Holman Phone: (419) 257-1327
MECHANICAL
Valid To: October 31, 2023 Certificate Number: 0562.01
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this
laboratory to perform the following automotive plastics tests:
Test Method: Test Name:
ASTM D412 Tensile
ASTM D523 Specular Gloss
ASTM D618 (A) Conditioning of Plastics
ASTM D624 (Die C) Tear Strength
ASTM D638 Tensile Properties
ASTM D792 (A) Density and Specific Gravity by Displacement
ASTM D1004 Initial Tear Resistance
ASTM D1203 (A) Volatile Loss
ASTM D1895 (A) Apparent Density, Bulk Factor, Pourability
ASTM D1921 Particle Size (Sieve Analysis)
ASTM D2240 Durometer Hardness (Shore A and D)
ASTM E1331 Color by Spectrophotometry Using Hemispherical Geometry
FMVSS 571.302 Flammability
FORD BN-102-01 (A) Low Temperature Flexibility
FORD BO-131-03 Interior Odor
ISO 3795 Determination of Burning Behavior of Interior Materials
SAE J323 (A) Cold Cracking (Mandrel Bend)
SAE J1351 Hot Odor for Insulation Materials
SAE J1545 Instrumental Color Difference Measurement
SAE J1756 Fogging Characteristics of Interior Automotive Materials (Photometric Only)
DOC-058151 Angle of Repose
1 Laboratory Developed Method
For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
https://www.avient.com/sites/default/files/2021-12/avient-sarl-czech-republic-branch-register-extract-dec-3-2021.pdf
Czech Republic Branch
Údaje platné ke dni: 3. prosince 2021 03:45 1/1
Výpis
z obchodního rejstříku, vedeného
Městským soudem v Praze
oddíl , vložka A 78870
Datum vzniku a zápisu: 30. srpna 2018
Spisová značka: A 78870 vedená u Městského soudu v Praze
Označení odštěpného
závodu:
Avient S.à r.l., Czech Republic Branch
Sídlo: Pobřežní 620/3, Karlín, 186 00 Praha 8
Identifikační číslo: 074 10 026
Právní forma: Odštěpný závod zahraniční právnické osoby
Předmět podnikání:
Výroba, obchod a služby neuvedené v přílohách 1 až 3 živnostenského zákona
Vedoucí odštěpného závodu:
LÁSZLÓ MEDNYÁNSZKY, dat. nar. 23. listopadu 1967
9400 Sopron, Ösvény 7, Maďarská republika
Zřizovatel - zahraniční osoba:
Avient S.à r.l.
9638 Pommerloch, Route de Bastogne 19, Lucemburské velkovévodství
Registrační číslo: B226205
Právní forma: společnost s ručením omezeným
Statutární orgán zřizovatele - zahraniční osoby:
Jednatel:
HOLGER HANS KRONIMUS, dat. nar. 26. ledna 1968
76571 Gaggenau, Adolf Dambach-Strasse 2, Spolková republika Německo
Den vzniku funkce: 4. července 2018
Den vzniku členství: 4. července 2018
Jednatel:
CHRISTOPH PALM, dat. nar. 16. května 1963
9638 Pommerloch, Route de Bastogne 19, Lucemburské velkovévodství
Den vzniku funkce: 4. července 2018
Den vzniku členství: 4. července 2018
Jednatel:
ZANETA GABRIELA POTOCZNY, dat. nar. 17. října 1974
9638 Pommerloch, route de Bastogne 19, Lucemburské velkovévodství
Den vzniku funkce: 27. února 2019
Den vzniku členství: 27. února 2019
Jednatel:
NORBERT MERKLEIN, dat. nar. 3. května 1964
4132 Muttenz, Rothausstrasse 61, Švýcarská konfederace
Den vzniku funkce: 18. ledna 2021
Den vzniku členství: 18. ledna 2021
Počet členů: 4
Společnost je platně vázána nebo zastupována vůči třetím osobám takto: má-li
Společnost více než jednoho jednatele, pak podpisem kteréhokoli jednatele.
https://www.avient.com/sites/default/files/2021-01/amendment-to-articles-commercial-registration-avient-corporation.pdf
The resolution was adopted pursuant to Ohio Revised Code section 1701.70(B)
(In this space insert the number 1 through 10 to provide basis for adoption.)
Upon review of the amendment document presented, my findings are as follows:
1.
The
fees are as follows:
Expedite 1 $100 2 Business Days
Expedite 2 $200 1 Business Day
Expedite 3 $300 4 Business Hours
2.