https://www.avient.com/sites/default/files/2021-06/colormatrix-select-brochure.pdf
COLORMATRIX SELECT WILL ENABLE:
• Immediate visibility of color
performance and cost data
for multiple formulation options
• On-demand color supply
• Full color choice with no minimum
order quantities
• Shorter development lead times
enabling faster market access and
multiple product introductions
• Assured global color consistency
• All the performance and process
efficiency advantages of ColorMatrix advanced
liquid colorants
MANUFACTURERS
TAKE CONTROL OF YOUR
COLOR SUPPLY
For manufacturers who use ColorMatrix Select will
be able to create and order color formulations online
in minutes.
CONVENTIONAL COLOR
DEVELOPMENT PROCESS
REDEFINED COLOR
DEVELOPMENT
Direct online access
to create new colors or view multiple color
formulations matching your specification
Full visibility
on color accuracy data performance,
price and regulatory status
Order samples
for dispatch within 24 hours
On-demand
color supply for production
Color Supplier
Designer
Brand
Target samples/
Target samples/
Matches
Trials
Manufacturer
ApprovalsApprovals Trials
Designer BrandManufacturer
ColorMatrix Select
Color Supplier
Designer
Brand
Target samples/
Target samples/
Matches
Trials
Manufacturer
ApprovalsApprovals Trials
Designer BrandManufacturer
ColorMatrix Select
Multiple rounds of sampling, trials and
approvals, usually over many weeks
COLORMATRIX
ADVANCED
LIQUID COLOR
SYSTEMS
Not all liquid colors are the same!
https://www.avient.com/sites/default/files/2025-01/Maxxam NHFR Non-Halogen Flame Retardant Polyolefins - Product Selector Guide EMEA.pdf
MAXXAM™ NHFR
NON-HALOGEN
FLAME RETARDANT
POLYOLEFINS
PRODUCT SELECTION GUIDE
Maxxam™ NHFR Polyolefins – Homopolymers
Disclaimer: The technical data provided here reflects the characteristic values of flame-retardant polypropylene materials and is not intended
as a product specification.
Product Name H15 H XF
V2 70
MF5200-5004
NHFR V2 HS
MF5200-5005
NHFR V2 RS H
MF5200-5006
NHFR V2 RS HS
H6 H XF
H20 H XF
H6 T/05 H XF
H6 T/10 H XF
H6 T/20 XF
H6 GF/10 XF
V070
H8 GF/20 XF
H12 GF/25 H
XF V0 70
H6 GF/30 XF
PE H XF
Polymer PP PE
Flammability V2 V2 V2 V2 V0 V0 V0 V0 V0 V0 V0 V0 V0 V0
UL Listed No No No No No No No No No No No No No Yes
Reinforcement Unfilled Unfilled Talc Talc Unfilled Unfilled Talc Talc Talc Glass Filled Glass Filled Glass Filled Glass Filled Unfilled
Density (g/cm3) 1.03 0.9 0.98 1.05 1.07 1.06 1.08 1.15 1.16 1.11 1.25 1.32 1.35 1
MFI,
230°C/2.16 kg 13 20 23 20 5.5 20 6 6 6 6 7 12 5.5
E-Modulus (Tensile
Modulus - Mpa) 1900 1500 2400 2600 2500 2500 2500 3000 3000 4300 6500 7500 8250 2000
Tensile Strength
(Mpa) 25 30 32 30 26 20 26 25 23 55 70 75 78 20
Elongation (%)
https://www.avient.com/sites/default/files/resources/TRA%2520-%25202016%2520Annual%2520Report%2520for%252017%2520Tideman.pdf
The amounts and values for the
facility(ies) identified below are accurate, based on reasonable estimates using available data.
The data for the facility(ies) that I represent are
hereby submitted to the programs identified below using the Single Window Reporting Application.
I also acknowledge that the data will be made public.
https://www.avient.com/sites/default/files/2021-06/fl.datasheet-strengthmembers.pdf
K58220T N/A Kevlar®
2480 LBs
(1125 KGs)
230 FT/LB
(154 M/KG)
Flat 2.81 mm N/A
Strength member in
cable application
Product ID
Polymer Jacket
Base Fiber
Break
Yield Geometry
Nominal
Diameter
Description
13.75mm
K/Hytrel
Hytrel Jacket Kevlar®
29000 LBs
(13154 KGs)
138 KGs/KM Round 13.75mm
Kevlar rope w/ Hytrel
12.5mm K/TPU TPU jacket Kevlar®
24000 LBs
(10885 KGs)
115 KGs/KM Round 12.5mm
Kevlar rope w/ Hytrel
7.87mm
K/MDPE
MDPE Jacket Kevlar®
24000 LBs
(10885 KGs)
50 KGs/KM Round 7.87mm
Kevlar w/ MDPE
.58mm C/PU TPU jacket Carbon
74 LBs
(33.6 KGs)
N/A Round/ Flat .58mm
Carbon w/ TPU
4.50mm
K/HDPE
HDPE jacket Kevlar®
2000 LBs
(907 KGs)
16 KGs/KM Round 4.06 mm
Kevlar w/ HDPE
POPULAR JACKETED STRENGTH MEMBERS
This data is provided for informational purposes only, and does not constitute a specification.
Uranusweg 3
8938 AJ Leeuwarden
The Netherlands
+31(0) 58 216 75 99
info@fiber-line.com
ABOUT FIBER-LINE®
NOTICE: The information and data contained herein do not constitute sales specifications.
https://www.avient.com/sites/default/files/2024-12/PKE grades for Powersports Application Bulletin.pdf
Gasoline - 30% glass-filled (GF) grade, dry as molded (DAM), room temperature
Testing methodology is an adaptation from ASTM D543
• Reapply freshly soaked gauze pad every 24 hours to prevent from drying out
• Repeat for a total of 72 hours
• Tensile properties recorded
*Chemical resistance data for DEET, motor oil, glass cleaner, and sunscreen available upon request
KEY CHARACTERISTICS
Figure 1
Figure 2
3.34
3.84
3.63
1.96
2.21
0.99
3.43
3.86 3.93
1.76
3.49
2.01
3.26
3.66 3.74
1.45
1.06 0.989
2.98
3.99
3.41
1.41
1.07
0.88
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
30% LGF PKE 30% LGF PA6 30% LGF PA66 30% SGF PKE 30% SGF PA6 30% SGF PA66
Ft
-lb
/in
Notched Izod Impact
ASTM D256
23C DAM 23C Conditioned -40C DAM -40C Conditioned
1.47
1.37 1.37
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
Glass-Filled PKE Glass-Filled PA6 Glass-Filled PA66
g/
cm
3
Density of Polyketone vs Nylon
ASTM D792
LESS MOISTURE ABSORPTION THAN NYLON
30% Short Glass Fiber (SGF) Comparison
Moisture uptake, environmental chamber 62% RH, 70°C
SIMILAR DENSITY TO NYLON
ASTM D792
COMPARABLE AND CONSISTENT IMPACT PERFORMANCE*
Notched Izod Impact (ASTM D256) of LGF and SGF for DAM and
Conditioned Materials
*3,000 hr weathering data available upon request
KEY CHARACTERISTICS
1.844.4AVIENT
www.avient.com
Copyright © 2024, Avient Corporation.
https://www.avient.com/sites/default/files/2023-01/ECCOH XL Cross-Linkable Solutions _8001_ Product Bulletin.pdf
Highly flame retardant—helps to prevent
a fire, or limit the damage if one starts
• Non-halogenated—in the case of a fire,
there are no acid gas emissions which can
damage equipment and buildings
• Low smoke—in the event of fire, people can
locate escape routes, and fire fighters can
quickly find the source of the fire
• Low toxicity—in the event of a fire, people
are not overcome by toxic fumes
• Low dripping—no flaming droplets which
can further propagate the fire or cause injury
• Low emission of corrosive gases when
burned—avoids potential damage to
electrical components and equipment, and
improves human safety
MARKETS AND APPLICATIONS
The ECCOH XL 8001 is a flame retardant material
for thermoset cable insulation.
https://www.avient.com/sites/default/files/2020-10/tpes-for-automotive-hvac-product-bulletin.pdf
GLS automotive TPEs are designed to improve driver and passenger safety and comfort.
https://www.avient.com/sites/default/files/2020-10/wire-cable-1-pager.pdf
APPLICATIONS: Power cables, Ethernet category cables, industrial cables, solar installation cables, coaxial cables,
fiber optics, hybrid cables
SYNCURE™
Cross-Linked Polyethylene for Power Cable Insulation
• Resistant to heat, oil, creep and abrasion
• Fast extrusion speeds
• UL 44 & UL 4703 flame performance
• UL/CSA bulletins
MAXXAM™ FR W&C
Flame Retardant Polypropylene for Category Cable
Insulation and Cross-Webs
• Alternative to FEP
• Low dielectric
• Thin wall extrusion capabilities
• UL 444 & plenum yellow card flame performance
FIRECON™
Flame Retardant Chlorinated Polyethylene
for Industrial Cable Jackets
• Resistance to harsh environments
• Low temperature properties
• UV resistance
• UL 44 flame performance
ECCOH™ LSFOH
Low Smoke and Fume, Non-Halogen for Insulation
and Jackets
• Low smoke and toxicity
• Improved fire safety
• Resistance to chemicals
• UL44 and CPR flame performance
ADDITIONAL SOLUTIONS
MAXXAM™ SY
Foamed Polypropylene for Coaxial Cable Insulation
SYNPRENE™
Flame Retardant Thermoplastic Elastomers
POLYMIX™
Customer Proprietary Formulations
For more information, please visit avient.com
or call +1.844.4AVIENT (+1.844.428.4368).
https://www.avient.com/sites/default/files/2021-03/in-house-plastisol-program-bulletin.pdf
Spills lead
to messy mixer areas which can create safety
issues and take hours to clean.
https://www.avient.com/sites/default/files/2023-03/Fiber-Line Global Product Selection Guide.pdf
FIBER-LINE™
High Performance
Synthetic Fibers
PRODUCT SELECTION GUIDE
FIBER-LINE™ HIGH PERFORMANCE SYNTHETIC FIBERS
Kevlar® Para-Aramid Nomex®
Meta-Aramid Vectran® LCP Zylon® PBO Carbon
Fiber UHMWPE PET Polyester Fiberglass Novoloid Technora®
Filament Yarn
TECHNICAL PROPERTIES Standard
High
Modulus
Standard
Standard
High
Standard
High
Standard
Standard
High
High
Tenacity
Low
Shrink E-Glass S-Glass Standard
Standard
Breaking Tenacity (g/d) 23.0 23.6 5.0 23.0 30.0 42.0 42.0 23.0 28.0 38 9.3 8.4 6.0 - 7.3 6.7 - 9.4 1.5 28.0
Specific Gravity (Ratio) 1.44 1.44 1.38 1.40 1.40 1.54 1.56 1.80 0.97 0.97 1.38 1.38 2.58 2.48 1.27 1.39
Elongation at Break (%) 3.5 2.5 30.0 3.8 2.8 3.5 2.5 1.5 3.5 3.1 14.6 19.5 3.5 5.5 30.0 - 40.0 4.6
Tensile Modulus (g/d) 555 885 125 600 830 1200 1800 1480 850 1250 120 70 200–275 140–170 2.5–5.0 590
Equilibrium Moisture Regain
at 55% RH (%) 5.0 5.0 4.5