https://www.avient.com/sites/default/files/2021-04/existencia-y-represnentacion-avient-colombia-sas.pdf
Fecha de configuración de la situación de control : 2015-09-01
RECURSOS CONTRA LOS ACTOS DE INSCRIPCIÓN
De conformidad con lo establecido en el Código de Procedimiento
Administrativo y de lo Contencioso Administrativo y la Ley 962 de
2005, los actos administrativos de registro, quedan en firme dentro
de los diez (10) días hábiles siguientes a la fecha de inscripción,
siempre que no sean objeto de recursos.
https://www.avient.com/sites/default/files/2024-10/Avient CDP Climate Change %26 Water Submission 20241001.pdf
10/01/2024, 04:45 pm
Avient
2024 CDP Corporate Questionnaire 2024
Word version
Important: this export excludes unanswered questions
This document is an export of your organization’s CDP questionnaire response.
Germany ETS
(3.5.2.1) % of Scope 1 emissions covered by the ETS
2.5
(3.5.2.2) % of Scope 2 emissions covered by the ETS
0
(3.5.2.3) Period start date
01/01/2023
(3.5.2.4) Period end date
12/31/2023
(3.5.2.5) Allowances allocated
54
0
(3.5.2.6) Allowances purchased
0
(3.5.2.7) Verified Scope 1 emissions in metric tons CO2e
724.94
(3.5.2.8) Verified Scope 2 emissions in metric tons CO2e
0
(3.5.2.9) Details of ownership
Select from:
☑ Facilities we own and operate
(3.5.2.10) Comment
Avient did not purchase allowances for greenhouse gas emissions from heating.
Row 2
(7.54.2.1) Target reference number
Select from:
☑ Oth 2
(7.54.2.2) Date target was set
365
01/01/2020
(7.54.2.3) Target coverage
Select from:
☑ Organization-wide
(7.54.2.4) Target type: absolute or intensity
Select from:
☑ Absolute
(7.54.2.5) Target type: category & Metric (target numerator if reporting an intensity target)
Engagement with suppliers
☑ Percentage of suppliers (by procurement spend) actively engaged on climate-related issues
(7.54.2.7) End date of base year
12/31/2020
(7.54.2.8) Figure or percentage in base year
39
(7.54.2.9) End date of target
12/31/2030
(7.54.2.10) Figure or percentage at end of date of target
90
(7.54.2.11) Figure or percentage in reporting year
366
70
(7.54.2.12) % of target achieved relative to base year
60.7843137255
(7.54.2.13) Target status in reporting year
Select from:
☑ Underway
(7.54.2.15) Is this target part of an emissions target?
https://www.avient.com/sites/default/files/2020-07/avient-abac-vietnam-200721_0.pdf
Chính sách Toàn
cầu về Chống Hối
lộ và Chống Tham
nhũng của Avient
Ban hành: Ngày 01/7/2020
Chính sách Toàn cầu về Chống Hối lộ và Chống Tham nhũng 1
Tầm quan trọng của việc Tuân thủ 1
Trách nhiệm của chúng ta 1
Hối lộ là gì?
https://www.avient.com/investors/events-presentations?page=4
May 01, 2015
https://www.avient.com/investors/events-presentations?page=8
Aug 01, 2012
https://www.avient.com/investors/events-presentations?page=5
May 01, 2014
https://www.avient.com/sites/default/files/2023-07/Avient-2022-Sustainability-Report.pdf
Patricia Verduin
HOME | Contents | Message from the CEO | About Us | People | Products | Planet | Performance | Metrics | Index Sustainability Report | 2022 4
https://www.avient.com/sites/default/files/2023-01/Corporate%20Governance%20Guidelines%20REV%202022.pdf
Our
Sustainability
Strategy
Sustainability is integral to achieving Avient’s
vision, mission and performance.
Visit Our Sustainability Site
HOME | Contents | Message from the CEO | About Us | People | Products | Planet | Performance | Metrics | Index Sustainability Report | 2022 46
https://www.avient.com/industries/healthcare
https://www.avient.com/products/polymer-colorants/healthcare-colorants/mevopur-healthcare-bio-based-polymer-solutions
https://www.avient.com/products/polymer-additives/healthcare-additives/mevopur-healthcare-functional-additives
https://www.avient.com/products/polymer-additives/healthcare-additives/mevopur-healthcare-functional-additives
https://www.avient.com/products/polymer-colorants/solid-color-masterbatches/remafin-ep-white-colorants
https://www.avient.com/sites/default/files/2023-01/Trilliant%20HC%20GF%20Polyketone%20_PK_%20Product%20Bulletin.pdf
https://www.avient.com/products/thermoplastic-elastomers/versaflex-hc-thermoplastic-elastomers
https://www.avient.com/sites/default/files/2023-03/Trilliant%20HC%20glass-filled%20PK%20-%20Biopharma%20Tubing%20Clamps.pdf
Transportation
Market Needs: Improve Efficiency, Extend Range,
Enable Circularity
As the demand for low- and zero-emission, energy-efficient transportation continues to grow
across all vehicle types, transportation requirements are evolving quickly.
AVERAGE
TENURE
8
years
AVERAGE
AGE
61
RACIAL
17%
Board of Directors Governance
GENDER
25%
female
TOTAL
DIVERSITY
42%
HOME | Contents | Message from the CEO | About Us | People | Products | Planet | Performance | Metrics | Index Sustainability Report | 2022 80
https://www.avient.com/sites/default/files/2023-01/Corporate%20Governance%20Guidelines%20REV%202022.pdf
Robert M.
https://www.avient.com/sites/default/files/2020-10/2020-gravi-tech-design-guide-.pdf
The boss should extend into the nominal wall of
the part, to avoid a thick region and possible sink
Figure 4 - Drafting Guidelines for
Nominal Wall Thickness
Cross section
showing draft
Figure 5 - Rib design guidelines
1/4˚—–1˚
2.5W
3W Min.
.01" R Min. or .25W
.75W for a low shrink material
.50W for a high shrink material
Figure 6 - Wall thickness changes due
to rib placement
16.00
14.00
12.00
10.00
8.00
6.00
4.00
2.00
5.00 10.00 15.00 20.00 25.00 30.00 35.00
Rib-height (mm)
M
ax
D
is
p
la
ce
m
en
t
M
ag
n
it
d
e
(m
m
)
FIGURE 4 - Drafing guidelines for
nominal wall thickness
FIGURE 5 - Rib design guidelines
FIGURE 7 - Wall thickness changes
due to rib placement
FIGURE 6 - Rib height vs. stiffness
10 Gravi-Tech
FIGURE 8 - Side Wall Boss Design Guidelines
Sink
Not Recommended Preferred Design
A
= Diameter
= A
= Primary Wall
= A
= 2A
FIGURE 9 - Guidelines Design Guidelines
4W
2W
.75W For a Low Shrink Material
.50W For a High Shrink Material
FIGURE 9 - Side wall boss design guidelines
FIGURE 10 - Gusset design guidelines
FIGURE 11 - Structural hole
area.
https://www.avient.com/sites/default/files/resources/Polyone%2520AR.pdf
D
O
LL
A
R
S
$391K
$1.65M
2008 2010 2012 2014 2016 2018
66672.indd main_11 3/25/19 4:00 PM
12
PERFORMANCE
66672.indd main_12 3/25/19 4:01 PM
13
2018 marked the ninth consecutive year of
adjusted EPS expansion at PolyOne, as we
delivered $2.43 per share.
EPS GROWTH
*EPS excluding special items and income from equity affiliates
2009 2010 2011 2012 2013 2014 2015 2016 2017 2018
$2.21
$0.13
$0.68
$0.82
$1.00
$1.31
$1.80
$1.96
$2.06
9 CONSECUTIVE YEARS OF
ADJUSTED EPS GROWTH
11%
INCREASE
IN DIVIDEND
$2.43
66672.indd main_13 3/25/19 4:01 PM
United States
Securities and Exchange Commission
Washington, DC 20549
FORM 10-K
ANNUAL REPORT PURSUANT TO SECTION 13 OR 15(d) OF THE SECURITIES EXCHANGE ACT OF 1934
For the fiscal year ended December 31, 2018
TRANSITION REPORT PURSUANT TO SECTION 13 OR 15(d) OF THE SECURITIES EXCHANGE ACT OF 1934
For the transition period from to .
Patricia Verduin
LEADERSHIP
66672.indd main_14 3/25/19 4:01 PM
POLYONE.COM
66672.indd main_15 3/25/19 4:01 PM
https://www.avient.com/sites/default/files/2020-10/luxury-closures-gravi-tech-design-guide-2.0-application-specific.pdf
The round at the bottom of the boss should
Figure 4 - Drafting Guidelines for
Nominal Wall Thickness
Cross section
showing draft
Figure 5 - Rib design guidelines
1/4˚—–1˚
2.5W
3W Min.
.01" R Min. or .25W
.75W for a low shrink material
.50W for a high shrink material
Figure 6 - Wall thickness changes due
to rib placement
16.00
14.00
12.00
10.00
8.00
6.00
4.00
2.00
5.00 10.00 15.00 20.00 25.00 30.00 35.00
Rib-height (mm)
M
ax
D
is
p
la
ce
m
en
t
M
ag
n
it
d
e
(m
m
)
FIGURE 4 - Drafing guidelines for
nominal wall thickness
FIGURE 5 - Rib design guidelines
FIGURE 7 - Wall thickness changes
due to rib placement
FIGURE 6 - Rib height vs. stiffness
10 Gravi-Tech
FIGURE 8 - Side Wall Boss Design Guidelines
Sink
Not Recommended Preferred Design
A
= Diameter
= A
= Primary Wall
= A
= 2A
FIGURE 9 - Guidelines Design Guidelines
4W
2W
.75W For a Low Shrink Material
.50W For a High Shrink Material
FIGURE 9 - Side wall boss design guidelines
FIGURE 10 - Gusset design guidelines
FIGURE 11 - Structural hole
be 10% of wall thickness.