https://www.avient.com/sites/default/files/2023-08/SEM Solutions for E-Batteries Infographic_v2.pdf
BATTERY JUNCTION BOX
Stat-Tech™ Static Dissipative & Electrically
Conductive Formulations
Surround™ EMI/RFI Shielding Formulations
• Integrated EMI/RFI shielding
• Easier to process vs metals
MODULE CONNECTOR
Therma-Tech™ Thermally Conductive Formulations
• Good stiffness and mechanical strength
EV CONNECTOR
Edgetek™ PKE Polyketone Formulations
• Excellent chemical resistance
• Low moisture uptake
• Non-halogenated flame retardant performance
• Colorable (RAL Orange)
• Reduced carbon footprint vs PA6 and PA66
COOLING SYSTEM
Therma-Tech™ Thermally
• Tensile strength
• Chemical resistance
BATTERY FRAME
Maxxam™ FR Flame Retardant Polyolefin Formulations
Edgetek™ Engineered Polymer Formulations
Polystrand™ Continuous Glass Fiber Reinforced Thermoplastics
• Non-halogenated flame retardant
HOUSING TRAY
OnForce™ Long Glass Fiber Reinforced
Polypropylene Composites
Stat-Tech™ Static Dissipative & Electrically
Conductive Formulations
Polystrand™ Continuous Glass Fiber
Reinforced Thermoplastics
• Design integration & freedom
• Structural performance
• EMI shielding
BATTERY MANAGEMENT CONTROLLER
Stat-Tech™ Static Dissipative & Electrically Conductive Formulations
Surround™ EMI/RFI Shielding Formulations
• Integrated EMI/RFI shielding
• Easier to process vs metals
BATTERY HOUSING/COVER
OnForce™ Long Glass Fiber Reinforced Polypropylene Composites
Complēt™ Long Fiber Reinforced Structural Thermoplastics
• Metal replacement
• Lightweighting
• Structural performance
• Design integration & freedom
Polystrand™ Continuous Glass Fiber
• Localized biaxial reinforcement
• Impact performance
• Overmolding compatibility
• Integrated assembly point stiffening
ENGINEERED MATERIALS FOR EV BATTERIES
CELL MODULE
Therma-Tech™ Thermally
Conductive Formulations
• Good stiffness and
mechanical strength
UNDERBODY PROTECTION
Polystrand™ Continuous Glass Fiber
• Superior impact performance
• Significantly lighter than steel
• Simplified integration with housing
• Corrosion resistance
https://www.avient.com/sites/default/files/2021-06/maxxam-fr-battery-pack-case-study-one-pager.pdf
POWER TOOL
COMPANY
B A T T E R Y P A C K
• HDPE based solution
• Meet flammability performance requirement for UL94 V-0
• Consistent color and global availability
• Provided global technical services to
enable consistent material quality in
Europe and Asia
• Tested and verified flame retardant
performance conforming to UL94 V-0 @
1.5 and 3.0 mm, GWFI 960°C
• Delivered a pre-colored, HDPE-based
solution for color uniformity globally
Maxxam ™ FR Formulation
KEY REQUIREMENTS
WHY AVIENT?
LEARN MORE
https://www.avient.com/products/engineered-polymer-formulations/flame-retardant-formulations/maxxam-fr-flame-retardant-polyolefin-formulations
https://www.avient.com/sites/default/files/2021-07/eccoh-optical-cable-sheath-case-study-one-pager.pdf
WIRE &CABLE
COMPANY
O P T I C A L C A B L E S H E A T H
• Excellent resistance to fungi and mildew
• Good UV resistance
• Meet flame retardant standard IEC 60332-3C
• Provided an anti-fungi solution with an ISO
846 rating of 0, showing no growth under
microscope
• Formulated solution to meet flammability
performance demands for IEC60332-2 or
GBT 18380.22-2008 compliance
• Complied with Biocidal Product Regulation
(EU) No528/2012 (BPR)
ECCOH™ Thermoplastic Formulation
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/products/engineered-polymer-formulations/eco-conscious-formulations/eccoh-cross-linkable-solutions
https://www.avient.com/sites/default/files/2022-07/ECCOH_ 5978 UV - Aerial Drop Cable Jacket - Applications Snapshot.pdf
CABLE
MANUFACTURER
A E R I A L D R O P C A B L E J A C K E T
• Pass clamp test requested by end customer
• Strong UV resistance & mechanical performance
• Excellent processing
• Good fire performance to pass CPR class Cca / Dca
• Low shrinkage (< 1%)
• Exceeded material fire performance
requirements and met all other performance
criteria
• Simplified supply chain with local
manufacture in Europe
• Enabled customer to run material at
optimum processing conditions by providing
support with machine set up
ECCOH™ 5978 UV Formulation
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/products/engineered-polymer-formulations/eco-conscious-formulations/eccoh-low-smoke-and-fume-non-halogen-formulations
Cable manufacturer
https://www.avient.com/sites/default/files/2021-10/maxxam-fr-category-cable-case-study.pdf
MAJOR W&C
PRODUCER
C A T E G O R Y C A B L E
• Flame retardance
• Replace fluorinated ethylene propylene (FEP)
• High tensile strength and high elongation at break
• Low dielectric constant (Dk) of 2.7-2.9 for data signal
integrity
• Satisfied stringent UL 444 requirements with
an FEP alternative to achieve cost savings
• Mitigated regulatory concerns with
comprehensive technical support during
testing and commercialization
• Met required melt strength parameters for
efficient profile extrusion
Maxxam™ FR Flame Retardant Polyolefin
Formulations
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/products/engineered-polymer-formulations/flame-retardant-formulations/maxxam-fr-flame-retardant-polyolefin-formulations
https://www.avient.com/sites/default/files/2023-05/Maxxam-Vacuum cleaner-application snapshot.pdf
GLOBAL VACUUM
CLEANER BRAND
B A T T E R Y P A C K & C O V E R
• Flame retardance to conform to UL 94 V-0 at 0.75 mm
• Easy to process and high-flow material to meet thin wall
part design
• Offered a UL 94 V-0 certified material to
fulfill specific customer requests
• Achieved excellent impact strength and
good flexural modulus for added durability
• Delivered an injection moldable PP with
high flow to meet thin-wall demands
Maxxam™ FR Flame Retardant Polyolefin
Formulations
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/products/engineered-polymer-formulations/flame-retardant-formulations/maxxam-fr-flame-retardant-polyolefin-formulations
https://www.avient.com/sites/default/files/2021-08/eccoh-5978-uv-case-study-one-pager.pdf
ECCOH™ 5978 UV formulations
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/products/engineered-polymer-formulations/eco-conscious-formulations/eccoh-low-smoke-and-fume-non-halogen-formulations
Cable manufacturer
https://www.avient.com/sites/default/files/2022-11/Bergamid -Battery Pack-Application Snapshot.pdf
SBD CORDLESS
POWER TOOL
B A T T E R Y P A C K
• PA66-based solution
• Meet flame retardant UL94 V-0 standard
• Pass 10-meter drop test
• Achieved flame retardance of UL94 V-0
rating @1.5 and 3.0 mm, GWFI 750 °C
• Offered material and high impact with good
laser marking performance strength
• Accomplished excellent surface appearance
with less visible fibers
• Provided shorter lead time and stronger
technical support than the competition
Bergamid™ FR Non-Halogen Flame Retardant
Formulation
KEY REQUIREMENTS
WHY AVIENT?
LEARN MORE
https://www.avient.com/products/engineered-polymer-formulations/flame-retardant-formulations/bergamid-fr-non-halogen-flame-retardant-formulations
https://www.avient.com/sites/default/files/2022-11/Bergamid_Battery Frame - Application Snapshot.pdf
SOLAR ENERGY
COMPANY
B A T T E R Y F R A M E
• Good dimensional stiffness at high operating temperatures
• Eco-conscious performance of a non-halogenated fire
retardant
• Easy processing
• Met regulatory requirements of UL 746C for
ultraviolet light, water, and immersion
exposures
• Delivered excellent high heat and eco-
friendly performance of non-halogenated
flame resistance
• Offered prompt development and on-site
technical services to accelerate the speed-
to-market
Bergamid™ FR Non-Halogen Flame
Retardant Formulations
KEY REQUIREMENTS
HIGH HEAT FLAME RESISTANCE
WHY AVIENT?
LEARN MORE
https://www.avient.com/products/engineered-polymer-formulations/flame-retardant-formulations/bergamid-fr-non-halogen-flame-retardant-formulations
https://www.avient.com/sites/default/files/2024-01/ECCOH 5983 - Power Cable - Case Study Snapshot.pdf
CABLE
MANUFACTURER
J A C K E T F O R P O W E R C A B L E
• High tear resistance > 11 N/mm
• High ESCR performance
• Cost efficient solution
• Hot pressure resistance above 80°C
• Provided a jacket solution that complies with
the LTS1 requirement as per BS 7655-6.1
• Enabled use in armored cables operating at
a maximum conductor temperature of 90°C
• Supported customer to optimize processing
of the new material
ECCOH™ LSFOH 5983 Formulation
KEY REQUIREMENTS
WHY AVIENT?
All Rights Reserved
https://www.avient.com/products/engineered-polymer-formulations/sustainable-formulations/eccoh-low-smoke-and-fume-non-halogen-formulations
Cable manufacturer