https://www.avient.com/knowledge-base/article/processing-styrenic-block-copolymer-tpes-gls
If that fails to correct the problem, you may have to increase the gate size.
A mold that is too cold, a melt that is too cold, and/or a gate that is too small lead to surface delamination (blistering) around the gate.
If that does not solve the problem, increase the gate size.
https://www.avient.com/knowledge-base/article/processing-styrenic-block-copolymer-tpes-gls?rtype[]=1164
If that fails to correct the problem, you may have to increase the gate size.
A mold that is too cold, a melt that is too cold, and/or a gate that is too small lead to surface delamination (blistering) around the gate.
If that does not solve the problem, increase the gate size.
https://www.avient.com/knowledge-base/article/injection-molding-mold-processing?rtype[]=1164
The larger the gate the longer the hold time required to achieve gate freeze.
Gate bulge.
Gate pucker.
https://www.avient.com/after-fx-post-press-special-effects
Cold peel (coated) paper will create a gloss finish, while hot split (uncoated) paper will create a smooth matte finish.
Maximize creativity and productivity for hot split, hot peel and cold peel transfers
https://www.avient.com/knowledge-base/article/overmolding-guide
Gate Design
Comparison of Gate Types
https://www.avient.com/knowledge-base/article/overmolding-guide?rtype[]=1164
Gate Design
Comparison of Gate Types
https://www.avient.com/knowledge-base/article/overmolding-guide?ind[]=6599
Gate Design
Comparison of Gate Types
https://www.avient.com/knowledge-base/article/overmolding-guide?pname[]=91
Gate Design
Comparison of Gate Types
https://www.avient.com/sites/default/files/2020-10/luxury-closures-gravi-tech-design-guide-2.0-application-specific.pdf
Edge Gate
This is the most common manual trim gate.
Sprue Gate
The sprue is gated directly into the part.
Tunnel Gate
A tunnel gate is the most common automatic
gate, and is a tapered gate that intersects the
part below the parting line.
https://www.avient.com/sites/default/files/2021-11/artisan-ar7300-pre-colored-formulation-processing-guide.pdf
MOLD DESIGN RECOMMENDATIONS
Gates
• Many different types of gates can be used, such as fan, tunnel, tab,
and edge gates
Gate thickness should be
50–75% of wall thickness
Avoid gating into thin part region.