https://www.avient.com/products/polymer-colorants/fiber-colorants/remafin-fiber-colorants
Explore the power of polymer solutions for hygiene & medical nonwovens
Discover how Avient's polymer colorants and additives can help increase the performance and appeal of nonwovens used in hygiene and medical applications
https://www.avient.com/products/polymer-colorants/colorant-dispersions/stan-tone-hc-plus-silicone-dispersions-healthcare
They are suitable for specialty medical devices, surgical devices, and other vital healthcare applications.
Portfolio of available dispersion colorants and additives for medical applications
https://www.avient.com/news/avient-feature-specialty-technologies-and-services-healthcare-mdm-west-2023
– February 2, 2023 – Avient will exhibit at Medical Design and Manufacturing (MD&M) West next week as part of the IME West show, highlighting its polymer solutions and services that can assist healthcare OEMs and molders in solving complex device and material challenges and help advance sustainability efforts.
Mevopur™ Healthcare Functional Additives comprise a portfolio of consistent, compliant functional additives to help protect or enhance the performance of polymers used in medical devices, diagnostics, or pharmaceutical packaging.
Colorant Chromatics™ Transcend™ Premier Healthcare Colorants are bright, high-temperature solutions developed specifically for medical applications.
https://www.avient.com/sites/default/files/2020-08/trilliant-case-study-1.pdf
MANUFACTURER BOOSTS
DISINFECTANT RESISTANCE
FOR MEDICAL DEVICE
HOUSINGS
HIGH PERFORMANCE MEDICAL FORMULATIONS
© 2020, All Rights Reserved
Avient Corporation, 33587 Walker Road, Avon Lake, Ohio USA 44012
To learn more about Trilliant HC, contact Avient
at +1.844.4AVIENT (1.844.428.4368).
Here’s a case in point: A leading manufacturer of
medical devices in North America had established
a great brand with excellent quality, but wanted
to improve the resistance of its PC/ABS equipment
housings to this new disinfection protocol.
https://www.avient.com/sites/default/files/2023-10/ISO13485 -2016 - 2021.2.20~2024.2.19 -EN.pdf
China
has been assessed and certified as meeting the requirements of
麟 ISO 13485:2016
EN ISO 13485:2016
’骥鑫馨瓤) For the foiowing actratEes
Design and manufacture of medical grade thermoplastic elastomers
for non-active medical devices and active medical devices
遴;舞蒸;撇蒸 (non-implantable)
:护、::于b入沙黔娜;舞睡莎:器器舞蟒檬非拟拐称群亘爸竺舀‘。
https://www.avient.com/sites/default/files/2023-01/Mevopur Healthcare Functional Additives for Bormed Resins Application Bulletin.pdf
Mevopur™ Healthcare Colorants and Formulations
and Mevopur™ Healthcare Functional Additives
for Bormed™ Resins
Mevopur™ Healthcare Colorants and Formulations
and Mevopur™ Healthcare Functional Additives
help medical device, diagnostics and
pharmaceutical packaging sectors meet the
growing challenges of product consistency,
compliance and reliability.
It is the responsibility of the medical device manufacturer and the person placing the medical device on the market to ensure compliance of the medical device with all applicable laws and regulations, including
the suitability of all raw materials and components used for its manufacture.
https://www.avient.com/sites/default/files/2020-10/case-study-one-pager-trilliant-xr-xray-glasses.pdf
MEDICAL EQUIPMENT
MANUFACTURER
S U R G I C A L X - R A Y G L A S S E S
• Replace lead while providing uniform shielding
performance
• Radiation shielding up to 140KeV
• Improve glasses design
• Compliance with Radiation Protection Regulation: Adult
eye exposure must be below 20 mSv per calendar year
• Conducted extensive testing to ensure comparable and
uniform shielding performance
• Improved geometric flexibility
• Lowered shielding component costs 30-50% by
eliminating machining and assembly steps (associated
with lead)
• Reduced weight of the glasses and enabled a more
ergonomic design
• Eliminated disposal concerns associated with lead
Trilliant™ XR Lead Replacement
Thermoplastics
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/products/engineered-polymer-formulations/conductive-signal-radiation-shielding-formulations/trilliant
Medical equipment manufacturer
https://www.avient.com/sites/default/files/2025-03/ISO 13485 2025.pdf
3
Certificate
Certified sites according to appendix
Scope
concentrates and specialty compounds for the
Healthcare and Medical device market.
Normative basis
EN ISO 13485:2016 Medical devices – Quality Management System
Page 1 of 3
Appendix of main certificate H61173
Central function Scope Norm / Revision Reg. no.
https://www.avient.com/sites/default/files/2022-03/Asia SEM Healthcare Product Selection Guide %281%29.pdf
SPECIALTY
ENGINEERED
MATERIALS FOR
HEALTHCARE
PRODUCT SELECTION GUIDE
Careful consideration must be given to materials used for medical
devices and their impact on patient safety.
Common applications include medical device overmolds, medical and biopharma tubing,
and gaskets and stoppers.
MATERIAL DESCRIPTION BASE RESIN
Trilliant™ HC2020 Copolyester
Trilliant™ HC8910/8920 Polyketone/ABS blend
Trilliant™ HC2120 Tritan
Trilliant™ HC3120 PC
Trilliant™ HC5210 PP
Trilliant™ HC6010 PA6
Trilliant™ HC6610 PA66
Trilliant™ GRV-NP-110-W PA12
TRILLIANT™ HC THERMOPLASTICS
• Chemically resistant replacement for FR PC/ABS,
FR PC/PET & FR COPE, providing UL 94 Yellow
Card V-0 flame rating at 1.5 mm, V-1 at 0.75 mm
thicknesses for a broad color spectrum
• Outperforms PC/ABS, PC/PET and COPE in
resistance to common disinfectants
• Retains tensile strength after 72-hour exposure
to common hospital disinfectants, and shows
better long-term chemical resistance as
compared to PC blends and COPE
• Exhibits good impact and temperature resistance
• Available in natural grades, standard medical
colors, or custom pre-colored products
• Medical device housings
• MRI, X-ray, CT scanner components
• Surgical instruments such as staplers, dissectors,
scissors
• Auto-injector pen
TRILLIANT™ HC
ELECTRICALLY
CONDUCTIVE
FORMULATIONS
• Consistent conductivity ensures repeatable
part performance and minimizes failures
related to inconsistent electrical conductivity
• High flow and easy processing facilitate filling
of thin wall parts and multiple cavity tools,
which enable faster cycle times and lower
per-unit part costs
• Superior durability reduces breakage and
resultant scrap related costs
• Less tendency to flash results in improved
appearance and less fluid retention in or on
the tip, thus driving greater accuracy and less
potential for cross-contamination
• High strength produces parts with greater
stiffness and warp resistance, again
minimizing scrap-related costs
• Conductive pipette tips
TEST
TEMS
SPECIFIC
GRAVITY
MELT FLOW
RATE
(230OC,
2.16KG)
TENSILE
FLEXURAL
FLEXURAL
MODULUS
IMPACT
STRENGTH
NOTCHED,
IZOD
SURFACE
RESISTIVITY
Method ASTM D-792 ASTM D-1238 ASTM D-638 ASTM D-790 ASTM D-790 ASTM D-256 ASTM D-257
Unit -- g/10min MPa MPa MPa J/m Ohms/sq.
https://www.avient.com/resource-center?document_type=59&document_subtype=117&page=0
Disinfectant Resistance for Medical Device Housings - Case Study
Manufacturer boosts disinfectant resistance for medical device housings using Trilliant HC High Performance Formulations