https://www.avient.com/sites/default/files/resources/Application%2520Bulletin%2520Resilience%2520HC.pdf
Rigid polymers typically used
to make housings for medical devices are
failing to resist these chemicals.
RESILIENCE™ HC OUTPERFORMS COMPETING POLYMERS
Design engineers are increasingly looking more frequently for better chemical resistance properties
in rigid device housings to combat the effects of disinfectants.
PolyOne conducted a comparative
study of polymer resistance to three common, harsh disinfectant chemistries.
https://www.avient.com/sites/default/files/2024-09/Chemical Resistance Technical Bulletin %281%29.pdf
MEDICAL DEVICE DISINFECTION—HOW TO PREVENT
CRACKING AND CRAZING
Understanding polymer performance is key to minimizing
disinfectant-related failures
DISINFECTANT-RELATED DAMAGE
ON POLYMER HOUSINGS
Strong chemicals used to reduce hospital-
acquired infections can damage equipment
and result in material failures, such as:
• Stress cracking
• Crazing
• Discoloration
CHEMICAL RESISTANCE REQUIREMENTS
VARY BY ENVIRONMENT
• Patient/exam rooms
• Operating and radiology rooms
• Reception areas
• Home (patient equipment & devices)
Healthcare devices must perform flawlessly in a myriad of challenging environments and engineers must
be certain their devices can withstand increasingly potent disinfectants, which have begun to outstrip
the performance of traditional polymers.
When it comes to material selection and options, you need a strong partner that understands
both polymers and the demands of the healthcare environment.
An independent lab tested the following polymers with various disinfectants to help customers choose
the material suitable to their specific application requirements.
https://www.avient.com/sites/default/files/2020-10/edgetek-peek-product-selection-guide.pdf
EDGETEK™
POLYETHERETHERKETONE (PEEK)
HIGH PERFORMING MELT-PROCESSABLE POLYMER
PRODUCT SELECTION GUIDE
Edgetek™ Polyetheretherketone (PEEK)
HIGH PERFORMING MELT-PROCESSABLE POLYMER
PROPERTY CONDITIONS TEST METHOD UNITS EDGETEK™
ET9800-0001 EM
EDGETEK™
ET9800-0002 RS
EDGETEK™
ET9800-0003 RS
EDGETEK™
ET9800-0004 RS EC
LUBRIONE™
LB9800-0001 AR
PHYSICAL
Mold Shrinkage -
Transverse – ASTM D955 in/in 0.014 0.010 0.011 0.009 0.014
MECHANICAL
Tensile Strength -
Yield – ASTM D638 PSI 14425 15640 23680 36500 19700
Tensile Elongation -
Yield – ASTM D638 % 5.4 3.0 2.2 1.5 0.2
Tensile Elongation -
Break – ASTM D638 % 19.5 3.1 2.2 1.5 1.9
Tensile Modulus – ASTM D638 PSI 555150 827700 1591300 5301000 2285600
Flexural Modulus – ASTM D790 PSI 529300 690700 1418300 3084300 1443400
Flexural Strength – ASTM D790 PSI 23500 27300 36000 52100 30300
IMPACT
Izod, Notched – ASTM D256 ft-lbs/in 1.0 0.7 1.1 1.3 0.6
Izod, Unnotched – ASTM D256 ft-lbs/in N.B. 13.1 15.3 13.8 5.0
THERMAL
Melting Point – – °C 343 343 343 343 343
Glass Transition (DSC) – – °C 143 143 143 143 143
Heat Deflection Temp 264 psi, Unannealed ASTM D648 °C 151 178 320 325 > 300
CLTE, Flow Direction 23°C to 140°C ASTM E831 cm/cm/°C 4.0E-05 5.5E-05 2.2E-05 7.0E-06 1.9E-05
CLTE, Flow Direction 140°C to 250°C ASTM E831 cm/cm/°C 9.7E-05 7.8E-05 2.3E-05 6.5E-06 2.2E-05
Polyetheretherketone (PEEK) is widely considered to be one of the highest performing melt-processable
polymers in the industry.
Avient’s specialty Edgetek™ PEEK formulations are capable of withstanding extreme
operating environments, and should be considered for use particularly where other engineered polymers
have failed.
https://www.avient.com/sites/default/files/2021-07/plastiward-flyer-global.pdf
THE BENEFITS
PLASTIWARD brings
counterfeiting protection of
plastic articles as close as
possible to the end consumers
by integrating taggants into
your products’ polymer
masterbatch, complying with
required regulations and
minimizing any impact on
production.
TURNKEY SYSTEM
PLASTIWARD is a robust,
customizable and cost-effective
turnkey system consisting of:
· proprietary taggants
integrated directly within
the polymer masterbatch
· a handheld detector
offering instant fake-
checking in the field
· a secure monitoring
platform on smartphone
or tablet capturing
field inspection data,
transmitted in real time
COMBINED EXPERTISE
At its core, PLASTIWARD
brings together SICPA’s
trusted expertise in brand
protection technologies
and processes, and Avient’s
recognized expertise in polymer
modification with colour and
performance additives.
https://www.avient.com/sites/default/files/2022-02/Edgetek-Surgical torque wrench-Application snapshot.pdf
S U R G I C A L T O R Q U E W R E N C H
SURGICAL DEVICE
MANUFACTURER
• Excellent wear resistance and lubricity
• Easy-to-mold
• Good chemical resistance, excellent disinfection
performance
• Dimensional stability
• Formulated a specialty thermoplastic that
retained physical properties and dimensional
stability under various testing conditions
• Provided a custom solution faster than
competitors to support accelerated speed to
market
Edgetek™ Engineered Polymer Formulation
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/products/engineered-polymer-formulations/general-engineered-formulations/edgetek-engineered-polymer-formulations
https://www.avient.com/sites/default/files/2023-04/Bergamid_ - Air gun bullet casing- Application Snapshot.pdf
AIRGUN BULLET
MANUFACTURER
B U L L E T C A S I N G
• Reduce weight by replacing metal
• Gunpowder free
• Less shooting energy from 100 Joules to 20 Joules
• Delivered a high-impact nylon formulation
with equal performance and 80% less weight
• Enabled improved shooting accuracy due to
the stable coefficient of friction(COF)
• Provided fast technical response and mold
trial support
Bergamid™ Polymer Formulation
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/products/engineered-polymer-formulations/general-engineered-formulations/nymax-bergamid-polymer?
https://www.avient.com/sites/default/files/resources/0514_02%2520PDI%2520ISO17025%2520Chemical_Extension%2520Cert2019.pdf
No. 0514.02) Revised 10/08/2019 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
POLYMER DIAGNOSTICS INC.
33587 Walker Road
Avon Lake, OH 44012
Ana De La Ree Phone: 440-930-3271
CHEMICAL
Valid To: December 31, 2019 Certificate Number: 0514.02
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this
laboratory to perform the following rubber and plastics tests:
Test Description:
Test Method or Standard:
Analysis of Volatile Contaminants from Polymers
(Chromatography)
VDA 277
FTIR (Fourier Transform Infrared) Spectroscopy
ASTM E1252 (Except 7.6, 11.2, and 11.4)
Flammability
Horizontal Burn of Self-Supporting Plastics ASTM D635; UL 94; IEC 60695-11-10
Horizontal Burn of Materials Used in Occupant
Compartments of Motor Vehicles
ASTM D5132; FMVSS 302 (49 CFR 571.302)
Vertical Burn, 20 mm ASTM D3801; UL 94; IEC 60695-11-10
Vertical Burn, 125 mm ASTM D5048; UL 94; IEC 60695-11-20
Oxygen Index ASTM D2863
FT1 Flame Test UL1581, Clause 1060;
UL2556/CSA C22.2 No 2556, Clause 9.3
Cable Flame Test UL1581, Clause 1061
VW1 Flame Test UL1581, Clause 1080;
UL2556/CSA C22.2 No 2556, Clause 9.4
FT2/FH Flame Test UL1581, Clause 1100;
UL2556/CSA C22.2 No 2556, Clause 9.1
FV-1 Flame Test UL1581, Clause 1060;
UL2556/CSA C22.2 No 2556, Clause 9.5
Thin Material Burning Test UL-94
Glow Wire Test
IEC 60695 2-10, 2-11, 2-12, 2-13
RVCM in PVC
ASTM D4443
(A2LA Cert.
Accredited Laboratory
A2LA has accredited
POLYMER DIAGNOSTICS INC.
https://www.avient.com/sites/default/files/2021-11/carbon-fiber-reinforced-product-bulletin.pdf
Carbon Fiber Reinforced Rods, Bars and Laminates
For Strengthening, Stiffening and Lightweighting
Carbon fiber reinforced polymer (CFRP) products
from Avient are continuous fiber polymer rods,
bars and laminates used in a variety of structural
strengthening, engineered weight reduction, and
repair applications in multiple industries.
To learn more about Avient carbon fiber
reinforced polymer solutions, contact Avient
at +1.844.4AVIENT (1.844.428.4368)
• Maximum thickness of 0.625 in/1.59 cm
• Full machining capabilities available
https://www.avient.com/sites/default/files/2023-05/Cesa Stat Product Selector Guide.pdf
Cesa™ Stat Antistatic Additives
PRODUCT SELECTION GUIDE
Polymers are typically non-conductive, allowing the
buildup of a static charge on the surface that can
attract dust or damage electronics stored within
packaging.
Cesa™ Stat temporary antistatic additives
create a conductive network on polymer surfaces
permitting dissipation of the electrical charges.
Cesa Stat Antistatic Additives - Standard Portfolio
POLYMER FAMILY MATERIAL PRODUCT NAME DOSAGE
Polyolefin PEATEC Cesa Stat PEATEC 1.0–4.0%
Polypropylene PPA0820051 Cesa Stat PPA0820051 1.0–4.0%
Polyamide ABAN698400 Cesa Stat 99027 5.0–15.0%
Polyester NBAN698440 Cesa Stat 3526 2.5–10.0%
Polycarbonate NCA0820011 Cesa Stat NCA0820011 5.0–8.0%
Styrenic SLAN698401 Cesa Stat 3301 3.0–7.5%
TPU RUA0820024 Cesa Stat RUA0820024 2.0–4.0%
Polyester FPA1660283 Hiformer™ liquid additives for polyolefins 0.10–0.50%
Cesa Stat Antistatic Additives can be used in combination with other Cesa masterbatches, and formulations can be customized for most applications.
https://www.avient.com/sites/default/files/2021-11/0514-02-dec2021.pdf
No. 0514.02) Revised 09/21/2021 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
POLYMER DIAGNOSTICS INC.
33587 Walker Road
Avon Lake, OH 44012
Ana De La Ree Phone: 440-930-3271
CHEMICAL
Valid To: December 31, 2021 Certificate Number: 0514.02
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this
laboratory to perform the following rubber and plastics tests:
Test Description:
Test Method or Standard:
Analysis of Volatile Contaminants from Polymers
(Chromatography)
VDA 277
FTIR (Fourier Transform Infrared) Spectroscopy
ASTM E1252 (Except 7.6, 11.2, and 11.4)
Flammability
Horizontal Burn of Self-Supporting Plastics ASTM D635; UL 94; IEC 60695-11-10
Horizontal Burn of Materials Used in Occupant
Compartments of Motor Vehicles
ASTM D5132; FMVSS 302 (49 CFR 571.302);
ISO 3785
Vertical Burn, 20 mm ASTM D3801; UL 94; IEC 60695-11-10
Vertical Burn, 125 mm ASTM D5048; UL 94; IEC 60695-11-20
Oxygen Index ASTM D2863
FT1 Flame Test UL1581, Clause 1060;
UL2556/CSA C22.2 No 2556, Clause 9.3
Cable Flame Test UL1581, Clause 1061
VW1 Flame Test UL1581, Clause 1080;
UL2556/CSA C22.2 No 2556, Clause 9.4
FT2/FH Flame Test UL1581, Clause 1100;
UL2556/CSA C22.2 No 2556, Clause 9.1
FV-1 Flame Test UL1581, Clause 1060;
UL2556/CSA C22.2 No 2556, Clause 9.5
Thin Material Burning Test UL-94
Glow Wire Test
IEC 60695 2-10, 2-11, 2-12, 2-13
RVCM in PVC
ASTM D4443
(A2LA Cert.
Accredited Laboratory
A2LA has accredited
POLYMER DIAGNOSTICS INC.