https://www.avient.com/sites/default/files/2023-10/2023 Syncure Wire and Cable Product Selection Guide.pdf
Syncure™ XLPE
Cross-linkable
Polyethylene
Formulations
FOR LOW VOLTAGE CABLES
PRODUCT SELECTION GUIDE
Syncure™ XLPE
MOISTURE CROSS-LINKABLE POLYETHYLENE INSULATION FOR LOW VOLTAGE CABLE SYSTEMS
SYSTEM S100FH S100FH-XUV S100FH-UV S100FV S100FV-UV S112NA S120NA S200FH S200FV
Applications Building Wire,
Building Wire,
Photo-Voltaic (PV)
Wire
Building Wire,
Teck-90 Pipe and Tube Building Wire, Tray Cable,
Service Entrance
Building Wire, Tray Cable,
Service Entrance
Specification UL 44 UL 44 UL 44, UL 4703 UL 44 UL 44 CSA 22.2 Suitable for
NSF 61 UL 44 UL 44
Wire Type XHHW-2, RHW-2, USE-2,
XHHW-2, RHW-2, USE-2,
SIS
XHHW-2, RHW-2,
USE-2, SIS, PV
XHHW-2, RHW-2,
XHHW-2, RHW-2,
USE-2, SIS, PV RW-90, Teck-90 – RHW-2, RHW, RHH,
XHHW-2, XHH, XHHW, SIS RHW, RHH, RHW-2
Components % 83% S1054A
17% V0022G RoHS
83% S1054A
17% V0022G-UV RoHS
70% S1054A
30% V0022G-UV RoHS
50% S1054A
50% V0044G RoHS
50% S1054A
50% V0044G-UV RoHS
95% S1054A
5% S1000B
95% S1016A
5% S1037B
78% S1054A
22% SC5400-0002 RoHS
MB ALT FR
50% S1054A
50% SC5400-0003 RoHS
MB ALT FR
Features Horizontal
Flame
Horizontal Flame,
UV Resistant,
Colors Possible
Horizontal Flame,
FV-1 Flame, UV Resistant,
Colors Possible
VW-1 VW-1, UV Resistant,
Colors Possible Non-FR Rigid Pipe Applications Horizontal Flame,
DBDPE-free VW-1, DBDPE-free
GENERAL PROPERTIES
Specific Gravity 1.01 1.02 1.10 1.31 1.31 0.92 0.95 1.01 1.31
Hardness Shore D,
10 Seconds 47 47 47 48 48 47 59 47 48
Gel 68 68 70 70 70 72 72 68 70
TENSILE PROPERTIES
Tensile Strength
(psi) 2800 2500 2650 3200 2650 2800 4500 2800 3200
Elongation % 400 400 540 470 540 400 80 400 470
Tensile
Retention % 100 100 97 110 110 95 75 95 100
Elongation
Retention % 90 90 94 100 100 90 75 90 93
ELECTRICAL
Dielectric
Strength (V/mil) 1000 1400 1400 1200 1200 1000 – 1000 1200
Dielectric
Constant 2.31 2.45 2.61 2.61 2.61 2.24 2.1 2.31 2.61
Dissipation
Factor % 0.0012 0.0080 0.008 0.0043 0.0043 0.0008 0.002 0.0012 0.0043
THERMAL
Temperature
Rating °C 90 90 90 90 90 90 125 90 90
Heat
Deformation % 10 5 5 5 5 10 10 10 5
The Syncure™ XLPE portfolio is a two-step, silane-
grafted, moisture cross-linkable polyethylene system.
https://www.avient.com/sites/default/files/2021-01/w-9-clariant-plastics-coatings-usa-llc-july-20201.pdf
See Regulations section 301.7701-2(c)(2)(iii).
Line 2
If you have a business name, trade name, DBA name, or disregarded
entity name, you may enter it on line 2.
Individual The individual
2.
https://www.avient.com/sites/default/files/2020-12/artisan-thermoplastics-nylon-processing-guide.pdf
Many different types of gates can be used such as pin, fan, tunnel,
tab and edge gates
2.
Full-round runners or modified trapezoid runners are the best designs
2.
Place vents at the end of fill and anywhere potential knit/weld lines will occur
2.
https://www.avient.com/sites/default/files/resources/Universal_Polyamide_Overmold_Thermoplastic_Elastomer.pdf
The wet out characteristic is determined by the
rheology of the TPEs as shown in Figure 2.
The data is reported as average force over 2 inch (5.08mm) of
pulling at speed of 2"/min (5.08mm/min).
As seen in Table 2, chemistry, types and aging have no
effect on bonding strength.
https://www.avient.com/investor-center/events/q4-2009-polyone-corporation-earnings-conference-call
Feb 04, 2010 2:00 PM EST
https://www.avient.com/sites/default/files/2023-07/Avient_RY 2022 CDP Verification Opinion Declaration_07-24-23%5B30%5D.pdf
Boundaries of the reporting company GHG emissions covered by the verification:
Operational Control
Global
Exclusions:
Fugitive refrigerants
Mobile Combustion
Types of GHGs: CO2, N2O, CH4
GHG Emissions Statement:
Scope 1: 34,627 metric tons of CO2 equivalent
Scope 2 (Location-Based): 167,333 metric tons of CO2 equivalent
Scope 2 (Market-Based): 99,465 metric tons of CO2 equivalent
Scope 3:
o Category 3 – Fuel and energy-related activities: 62,049 metric tons of CO2 equivalent
Data and information supporting the Scope 1 and Scope 2 GHG emissions assertion were in most cases
historical in nature and in some cases were estimated.
Energy:
o Diesel Fuel Consumption: 4,754,671 kWh
o Natural Gas Fuel Consumption: 184,415,668 kWh
o Renewable Energy Consumed - Self Generated (solar): 260,378 kWh
o Renewable Energy Consumed - Self Generated (Wind): 2,554,186 kWh
o Grid Electricity Consumed: 436,400,546 kWh
Page 2
WATER RESOURCES • ENVIRONMENTAL SERVICES • INDUSTRIAL HYGIENE • SAFETY • SUSTAINABILITY
Apex Companies, LLC • (800) 733‐2739 • www.apexcos.com
o Renewable Energy Credits (REC) Purchased: 100,691,000 kWh
o Renewable Electricity Consumed – Offsite: 128,982,866 kWh
Period covered by GHG emissions verification:
January 1, 2022 to December 31, 2022
GHG Reporting Protocols against which verification was conducted:
World Resources Institute (WRI)/World Business Council for Sustainable Development (WBCSD)
Greenhouse Gas Protocol, Corporate Accounting and Reporting Standard, Revised Edition (Scope 1 and 2)
and the GHG Protocol Scope 2 Guidance, an amendment to the GHG Protocol Corporate Standard
WRI/WBCSD Corporate Value Chain (Scope 3) Accounting and Reporting Standard
Verification Protocols used to conduct the verification:
ISO 14064-3 Second Edition 2019-04: Greenhouse gases - Part 3: Specification with guidance for the
verification and validation of greenhouse gas statements
Apex’s standard procedures and guidelines for external Assurance of Sustainability Reports and
International Standard on Assurance Engagements (ISAE) 3000 Revised, Assurance Engagements Other
than Audits or Reviews of Historical Financial Information (effective for assurance reports dated on or after
Dec. 15, 2015), issued by the International Auditing and Assurance Standards Board.
Verification Opinion:
Based on the verification process and procedures conducted to a limited assurance level of the GHG emissions
statement shown above, Apex found no evidence that the GHG emissions statement:
is not materially correct and is not a fair representation of the GHG emissions data and information; and
has not been prepared in accordance with the WRI/WBCSD GHG Protocol Corporate Accounting and
Reporting Standard (Scope 1 and 2), and WRI/WBCSD Greenhouse Gas Protocol Corporate Value Chain
Accounting and Reporting Standard (Scope 3).
https://www.avient.com/sites/default/files/2023-03/AvientRY 2021 CDP Verification Opinion Declaration_07-26-22r%5B96%5D.pdf
Boundaries of the reporting company GHG emissions covered by the verification:
Operational Control
Global
Exclusions:
Fugitive refrigerants
Types of GHGs: CO2, N2O, CH4
GHG Emissions Statement:
Scope 1: 18,242 metric tons of CO2 equivalent
Scope 2 (Location-Based): 134,244 metric tons of CO2 equivalent
Scope 2 (Market-Based): 85,892 metric tons of CO2 equivalent
Scope 3:
o Category 3 – Fuel and energy-related activities (electricity transportation and distribution losses only):
8,777 metric tons of CO2 equivalent
Data and information supporting the Scope 1 and Scope 2 GHG emissions assertion were in most cases
historical in nature and in some cases were estimated.
Energy:
o Diesel Fuel Consumption: 7,268,012 kWh
o Natural Gas Fuel Consumption: 90,498,342 kWh
o Renewable Energy - Self Generated (solar): 252,779 kWh
o Renewable Energy - Self Generated (Wind): 2,399,531 kWh
o Electric Power: 339,815,274 kWh
Page 2
WATER RESOURCES • ENVIRONMENTAL SERVICES • HEALTH & SAFETY • CLIMATE CHANGE
Apex Companies, LLC • (800) 733-2739 • www.apexcos.com
o Renewable Energy Credit (REC): 121,411,062 kWh
o Renewable Power – Offsite: 27,119,749 kWh
Period covered by GHG emissions verification:
January 1, 2021 to December 31, 2021
GHG Reporting Protocols against which verification was conducted:
World Resources Institute (WRI)/World Business Council for Sustainable Development (WBCSD)
Greenhouse Gas Protocol, Corporate Accounting and Reporting Standard, Revised Edition (Scope 1 and 2)
and the GHG Protocol Scope 2 Guidance, an amendment to the GHG Protocol Corporate Standard
WRI/WBCSD Corporate Value Chain (Scope 3) Accounting and Reporting Standard
Verification Protocols used to conduct the verification:
ISO 14064-3 Second Edition 2019-04: Greenhouse gases - Part 3: Specification with guidance for the
verification and validation of greenhouse gas statements
Apex’s standard procedures and guidelines for external Assurance of Sustainability Reports and
International Standard on Assurance Engagements (ISAE) 3000 Revised, Assurance Engagements Other
than Audits or Reviews of Historical Financial Information (effective for assurance reports dated on or after
Dec. 15, 2015), issued by the International Auditing and Assurance Standards Board.
Verification Opinion:
Based on the verification process and procedures conducted to a limited assurance level of the GHG emissions
statement shown above, Apex found no evidence that the GHG emissions statement:
is not materially correct and is not a fair representation of the GHG emissions data and information; and
has not been prepared in accordance with the WRI/WBCSD GHG Protocol Corporate Accounting and
Reporting Standard (Scope 1 and 2), and WRI/WBCSD Greenhouse Gas Protocol Corporate Value Chain
Accounting and Reporting Standard (Scope 3).
https://www.avient.com/resources/safety-data-sheets?page=2037
TRANS NAT PP GREEN GLOW 2
TRANS BLUE PP BLUE GLOW 2
GLO GREEN 2
https://www.avient.com/resources/safety-data-sheets?page=2848
M1641B 1/2 PART BLUE CPSC
9148-2 BLACK OIL RESISTANT PLASTISOL
5533 Med, 20% BaSO4, 2% TiO2, Stab
https://www.avient.com/resources/safety-data-sheets?page=6741
DK GREY 2
LT GREY 2
AMBER 2 - DRIED