https://www.avient.com/industries/packaging/household-packaging/surface-care
Customized Cesa™ WithStand Antimicrobial Additives were used for medical gowns to support compliance and performance.
Chair Lumbar Support
Dynaflex™ TPE delivers the right support, look and feel for leading seating manufacturer's lumbar support
https://www.avient.com/industries/packaging/personal-care-packaging/sun-care
Customized Cesa™ WithStand Antimicrobial Additives were used for medical gowns to support compliance and performance.
Chair Lumbar Support
Dynaflex™ TPE delivers the right support, look and feel for leading seating manufacturer's lumbar support
https://www.avient.com/industries/packaging/household-packaging/fabric-care
Customized Cesa™ WithStand Antimicrobial Additives were used for medical gowns to support compliance and performance.
Chair Lumbar Support
Dynaflex™ TPE delivers the right support, look and feel for leading seating manufacturer's lumbar support
https://www.avient.com/sites/default/files/resources/0514_02%2520PDI%2520ISO17025%2520Chemical_Extension%2520Cert2019.pdf
No. 0514.02) Revised 10/08/2019 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
POLYMER DIAGNOSTICS INC.
33587 Walker Road
Avon Lake, OH 44012
Ana De La Ree Phone: 440-930-3271
CHEMICAL
Valid To: December 31, 2019 Certificate Number: 0514.02
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this
laboratory to perform the following rubber and plastics tests:
Test Description:
Test Method or Standard:
Analysis of Volatile Contaminants from Polymers
(Chromatography)
VDA 277
FTIR (Fourier Transform Infrared) Spectroscopy
ASTM E1252 (Except 7.6, 11.2, and 11.4)
Flammability
Horizontal Burn of Self-Supporting Plastics ASTM D635; UL 94; IEC 60695-11-10
Horizontal Burn of Materials Used in Occupant
Compartments of Motor Vehicles
ASTM D5132; FMVSS 302 (49 CFR 571.302)
Vertical Burn, 20 mm ASTM D3801; UL 94; IEC 60695-11-10
Vertical Burn, 125 mm ASTM D5048; UL 94; IEC 60695-11-20
Oxygen Index ASTM D2863
FT1 Flame Test UL1581, Clause 1060;
UL2556/CSA C22.2 No 2556, Clause 9.3
Cable Flame Test UL1581, Clause 1061
VW1 Flame Test UL1581, Clause 1080;
UL2556/CSA C22.2 No 2556, Clause 9.4
FT2/FH Flame Test UL1581, Clause 1100;
UL2556/CSA C22.2 No 2556, Clause 9.1
FV-1 Flame Test UL1581, Clause 1060;
UL2556/CSA C22.2 No 2556, Clause 9.5
Thin Material Burning Test UL-94
Glow Wire Test
IEC 60695 2-10, 2-11, 2-12, 2-13
RVCM in PVC
ASTM D4443
(A2LA Cert.
Please verify this organization’s acceptance status by using the CPSC’s searchable database,
located at http://www.cpsc.gov/cgi-bin/labsearch/.
http://www.cpsc.gov/cgi-bin/labsearch/
For the tests to which this accreditation applies, please refer to the laboratory’s Chemical Scope of Accreditation.
https://www.avient.com/sites/default/files/resources/Ramos%2520IATF%252016949-2016%2520exp%25207-10-2021_0.pdf
https://pgplus.bsigroup.com/CertificateValidation/CertificateValidator.aspx?
Including the following remote support functions:
Polyone Corporation
33587 Walker Road
Avon Lake, OH 44012
USA
Audited by ABS Quality evaluations
Product Design, Purchasing, Customer Service and Strategic
Planning
Location Registered Activities
BSI Certificate Number: 85585
IATF Number: 0315491
Certification Date: 2018-07-11 Latest Issue: 2018-07-11 Expiry Date: 2021-07-10
Page: 2 of 2
This certificate remains the property of BSI and shall be returned immediately upon request.
https://pgplus.bsigroup.com/CertificateValidation/CertificateValidator.aspx?
https://www.avient.com/sites/default/files/2021-11/0514-02-dec2021.pdf
No. 0514.02) Revised 09/21/2021 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
POLYMER DIAGNOSTICS INC.
33587 Walker Road
Avon Lake, OH 44012
Ana De La Ree Phone: 440-930-3271
CHEMICAL
Valid To: December 31, 2021 Certificate Number: 0514.02
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this
laboratory to perform the following rubber and plastics tests:
Test Description:
Test Method or Standard:
Analysis of Volatile Contaminants from Polymers
(Chromatography)
VDA 277
FTIR (Fourier Transform Infrared) Spectroscopy
ASTM E1252 (Except 7.6, 11.2, and 11.4)
Flammability
Horizontal Burn of Self-Supporting Plastics ASTM D635; UL 94; IEC 60695-11-10
Horizontal Burn of Materials Used in Occupant
Compartments of Motor Vehicles
ASTM D5132; FMVSS 302 (49 CFR 571.302);
ISO 3785
Vertical Burn, 20 mm ASTM D3801; UL 94; IEC 60695-11-10
Vertical Burn, 125 mm ASTM D5048; UL 94; IEC 60695-11-20
Oxygen Index ASTM D2863
FT1 Flame Test UL1581, Clause 1060;
UL2556/CSA C22.2 No 2556, Clause 9.3
Cable Flame Test UL1581, Clause 1061
VW1 Flame Test UL1581, Clause 1080;
UL2556/CSA C22.2 No 2556, Clause 9.4
FT2/FH Flame Test UL1581, Clause 1100;
UL2556/CSA C22.2 No 2556, Clause 9.1
FV-1 Flame Test UL1581, Clause 1060;
UL2556/CSA C22.2 No 2556, Clause 9.5
Thin Material Burning Test UL-94
Glow Wire Test
IEC 60695 2-10, 2-11, 2-12, 2-13
RVCM in PVC
ASTM D4443
(A2LA Cert.
Please verify this
organization’s acceptance status by using the CPSC’s searchable database, located at
http://www.cpsc.gov/cgi-bin/labsearch/.
http://www.cpsc.gov/cgi-bin/labsearch/
For the tests to which this accreditation applies, please refer to the laboratory’s Chemical Scope of Accreditation.
https://www.avient.com/sitemap
Regulatory and Compliance Agency Support
Technical Support Request
Support Services
https://www.avient.com/simpli5-understanding-performance-factors-quality-ink
Technical Support: Is help readily available?
https://www.avient.com/company/sustainability/sustainability-report/goals-commitments/about-us/what-we-do-materials-science
Our formulation expertise supports materials science decisions, while our processing expertise guides customers to use the materials properly.
https://www.avient.com/company/purpose-strategic-framework
We have conducted extensive portfolio prioritization and identified growth vectors to both catalyze growth in our core and to build businesses in high growth markets supported by secular trends.