https://www.avient.com/resources/safety-data-sheets?page=5557
MC-54033PV TAN 20 W/UV
MC-54037PV TAN 45 W/UV
MC-54040PV TAN 66 W/UV
https://www.avient.com/resources/safety-data-sheets?page=5759
GREEN OPTIMIZED LDR W/UV
BEIGE OPTIMIZED LDR W/UV
BLUE OPTIMIZED NO UV
https://www.avient.com/resources/safety-data-sheets?page=5671
MC-53989NY AK-CANVAS W/UV
MC-54047PV CLAY 69 W/UV
MC-61360PP BLAZE ORANGE W/UV
https://www.avient.com/sites/default/files/2024-05/Avient Zertifikat englisch - 2024.pdf
Bergmann GmbH
Adolf-Dambach-Str. 2-4
76571 Gaggenau
the introduction and application of a management system according to
ISO 50001:2018
scope:
Delelopment and production of technical Polymers; at the sites according to
appendix.
Bergmann GmbH
Adolf-Dambach-Str. 2-4
76571 Gaggenau
c/o Avient ECCOH High Performance Solutions GmbH
Oldendorfer Straße 9, 49324 Melle
Production of technical Polymers
https://www.avient.com/sites/default/files/2020-12/onflex-interior-tray-english.pdf
TIER 2 SUPPLIER
I N T E R I O R T R A Y S
• A low FOG material with low odor
• Low gloss finish
• Easy processability
• Enabled easier processing than the
incumbent TPE-v
• Eliminated pre-drying step and delivered
pre-colored material, improving process
efficiencies
• Met needs for low fogging (≤2 mg)
and low odor (≤3.0) with low gloss finish
OnFlex™ S EH 80A-3S7005 Thermoplastic
Elastomer
KEY REQUIREMENTS
WHY AVIENT?
https://www.avient.com/sites/default/files/2021-04/avient-colorants-netherlands-b.v.-extract-coc-apr-12-2021.pdf
titel
20
21
-0
4-
12
1
4:
06
:2
8
Business Register extract
Netherlands Chamber of Commerce
CCI number 34246357
Page 1 (of 2)
Legal entity
RSIN 815617781
Legal form Besloten Vennootschap (comparable with Private Limited Liability Company)
Statutory name Avient Colorants Netherlands B.V.
The Chamber of Commerce recommends that this document be viewed in digital form so that its
integrity is safeguarded and the signature remains verifiable.
20
21
-0
4-
12
1
4:
06
:2
8
under number CHE-112.279.714
Sole shareholder since 20-10-2015 (registration date: 03-11-2015)
Board members
Name Borst, Rainer Erich
Date of birth 10-10-1961
Date of entry into office 01-07-2020 (registration date: 06-07-2020)
Title Director
Name Kamalak, Ihsan
Date of birth 21-08-1985
Date of entry into office 01-07-2020 (registration date: 06-07-2020)
Title Director
Name Merklein, Norbert
Date of birth 03-05-1964
Date of entry into office 05-03-2021 (registration date: 30-03-2021)
Extract was made on 12-04-2021 at 14.06 hours.
Business Register extract
Netherlands Chamber of Commerce
CCI number 34246357
Page 2 (of 2)
N/A
2021-04-12T14:06:40+0200
Utrecht
Kamer van Koophandel
Dit document is digitaal ondertekend
2021-04-12T14:06:42+0200
https://www.avient.com/sites/default/files/2024-09/Avient_RY 2023 CDP Verification Opinion Declaration.pdf
Boundaries of the reporting company GHG emissions covered by the verification:
• Operational Control
• Global
Exclusions:
• Fugitive refrigerants from units
Energy:
o Diesel Fuel Consumption: 2,868,323 kWh
o Natural Gas Fuel Consumption: 178,696,287 kWh
o Renewable Energy Consumed - Self Generated (solar): 681,059 kWh
o Renewable Energy Consumed - Self Generated (Wind): 2,385,048 kWh
o Grid Electricity Consumed: 409,650,679 kWh
o Renewable Energy Credits (REC) Purchased: 112,413,420 kWh
o Renewable Electricity Consumed – Offsite: 138,415,253 kWh
Page 2
Period covered by GHG emissions verification:
• January 1, 2023 to December 31, 2023
Global Warming Potential (GWP) and emission factor data sets:
• IPCC GWP: AR6
• USEPA Emission Factor Hub, released 2024
• USEPA eGRID, released 2024
• Final Rule (40 CFR 98) - Industrial Sector 2013
• DEFRA, released 2023
• IEA, released 2023
• European Residual Mix, released 2022 v2.0
GHG Reporting Protocols against which verification was conducted:
• World Resources Institute (WRI)/World Business Council for Sustainable Development (WBCSD)
Greenhouse Gas Protocol, Corporate Accounting and Reporting Standard, Revised Edition (Scope 1 and 2)
and the GHG Protocol Scope 2 Guidance, an amendment to the GHG Protocol Corporate Standard
• WRI/WBCSD Corporate Value Chain (Scope 3) Accounting and Reporting Standard
Verification Protocols used to conduct the verification:
• ISO 14064-3 Second Edition 2019-04: Greenhouse gases - Part 3: Specification with guidance for the
verification and validation of greenhouse gas statements
• Apex’s standard procedures and guidelines for external Assurance of Sustainability Reports and
International Standard on Assurance Engagements (ISAE) 3000 Revised, Assurance Engagements Other
than Audits or Reviews of Historical Financial Information (effective for assurance reports dated on or after
Dec. 15, 2015), issued by the International Auditing and Assurance Standards Board.
Page 3
Verification Opinion:
Based on the verification process and procedures conducted to a limited assurance level of the GHG emissions
statement shown above, Apex found no evidence that the GHG emissions statement:
• is not materially correct and is not a fair representation of the GHG emissions data and information; and
• has not been prepared in accordance with the WRI/WBCSD GHG Protocol Corporate Accounting and
Reporting Standard (Scope 1 and 2), and WRI/WBCSD Greenhouse Gas Protocol Corporate Value Chain
Accounting and Reporting Standard (Scope 3).
https://www.avient.com/sites/default/files/2023-10/Syncure XLPE 200 Series DBDPE-free Grades Product Bulletin.pdf
This literature shall NOT operate as permission, recommendation, or inducement to practice any patented invention without permission of the patent owner.
1.844.4AVIENT
www.avient.com
System Syncure XLPE
S200FH
Syncure XLPE
S200FV
Applications Building Wire, Tray Cable,
Service Entrance
Building Wire, Tray Cable,
Service Entrance
Specification UL 44 UL 44
Wire Type RHW-2, RHW, RHH, XHHW-2,
XHH, XHHW, SIS RHW, RHH, RHW-2
Components
78% S1054A
22% SC5400-0002 RoHS
MB ALT FR
50% S1054A
50% SC5400-0003 RoHS
MB ALT FR
Features Horizontal Flame, DBDPE-free VW-1, DBDPE-free
General Properties
Specific Gravity (g/cm3) 1.01 1.31
Hardness Shore D, 10sec 47 48
Gel % 68 70
Tensile Properties
Tensile Strength (psi) 2800 3200
Elongation % 400 470
Tensile Retention % 95 100
Elongation Retention % 90 93
Electrical
Dielectric Strength (V/mil) 1000 1200
Dielectric Constant 2.31 2.61
Dissipation Factor % 0.0012 0.0043
Thermal
Temperature Rating °C 90 90
Heat Deformation % 10 5
TECHNICAL PROPERTIES
https://www.avient.com/sites/default/files/2023-10/Cesa Flame Retardant Additives PTFE-free and Non-halogen for Polycarbonate Product Bulletin_A4.pdf
Avient’s PTFE-free and non-halogen Cesa™ Flame
Retardant Additives for polycarbonate are
formulated without PTFE and are non-halogen in
accordance with the IEC 61249-2-21 standard.
APPLICATIONS
• Electrical and electronic enclosures
and housings
• Junction boxes
• Switches, connectors and plugs
• Power outlet components
• Covers and windows in E&E parts
BENEFITS
• Formulated without PTFE which is typically
used as anti-drip agent
• Non-halogen in accordance with the
IEC 61249-2-21 standard
• Achieves GWFI 960°C temperature
(with max. 30 sec post combustion time)
according to IEC 60695-2-12
• Can be combined with colors and other
additives for added convenience
and increased performance
PRODUCT OVERVIEW
Copyright © 2023, Avient Corporation.
https://www.avient.com/sites/default/files/2025-07/Toluca IATF 2025.pdf
Page 1 of 2
https://abs.ez2xs.com
IATF 16949:2016 , First Edition
Certificate Of Conformance
ANNEX
Certificate No: 63431
IATF No: 0566308
Avient de México, S.A. de C.V.
Page 2 of 2
https://abs.ez2xs.com