https://www.avient.com/sites/default/files/2024-08/Automotive General Design Technology Guide.pdf
We have the ability to
deliver custom solutions supported by molded-in color plastics
testing procedures that can help you achieve your design and
engineering specifications.
You have the responsibility to conduct full-scale end-product performance testing
to determine suitability in your application, and you assume all risk and liability arising from your use of the information and/or use or handling of any product.
https://www.avient.com/sites/default/files/2024-12/Complet PKE Product Bulletin.pdf
You have the responsibility to conduct full-scale end-product performance testing
to determine suitability in your application, and you assume all risk and liability arising from your use of the information and/or use or handling of any product.
TECHNICAL
PROPERTIES(1)
TEST
METHOD
Complēt
LGF30-PKE NAT
Complēt
LGF40-PKE NAT
Complēt
LGF50-PKE NAT
Physical
Density/Specific Gravity ASTM D792 1.47 1.54 1.66
Mechanical
Tensile Strength (Yield) ASTM D638 21,100 psi 24,700 psi 26,400 psi
Tensile Modulus(2) ASTM D638 1,150,000 psi 1,570,000 psi 2,150,000 psi
Flexural Modulus(3) ASTM D790 1,120,000 psi 1,480,000 psi 2,030,000 psi
Flammability (non-PFAS options available)
Flame Rating @ 1.5 mm UL 94 V-0 V-0 —
COLD IMPACT PERFORMANCE
Ft
-l
b/
in
Data based on single lot of lab-generated samples.
https://www.avient.com/sites/default/files/2024-07/Colorants _ Additives for Appliances Brochure.pdf
We offer a wide range of color concentrates for different polymer grades, from standard to
engineering polymers, that fulfill the vertical burning (V-0; V-1; V-2) and horizontal burning (HB) tests.
Recyclability Assessment
at CycleWorks™
Our Cycleworks™ Innovation Center specializes
in testing and evaluating recycling solutions.
You have the responsibility to conduct full-scale end-product performance testing
to determine suitability in your application, and you assume all risk and liability arising from your use of the information and/or use or handling of any product.
https://www.avient.com/sites/default/files/2020-08/2020-composite-springs-product-selection-install-guide.pdf
TYPICAL PROPERTIES
Sample thickness 0.25 in/6.35mm
TEMPERATURE
FLEXURAL STRENGTH ASTM
D790
FLEXURAL MODULUS ASTM
D790
°F °C ksi MPa msi GPa
-60 -51 173 1193 5.00 34.48
70 21 155 1069 5.11 35.23
160 71 138 952 5.04 34.75
250 121 110 758 4.70 32.41
300 149 78 538 4.22 29.10
-60 -51 176 1211 5.64 38.92
70 21 143 989 5.36 36.98
160 71 120 824 5.57 38.41
250 121 61 423 4.82 33.24
-60 -51 163 1125 4.19 28.88
70 21 120 824 3.85 26.51
160 71 86 595 3.83 26.44
250 121 40 274 3.19 22.00
G
la
ss
/E
po
xy
H
ig
h
Te
m
p
Ep
ox
y/
G
la
ss
G
la
ss
/V
in
yl
E
st
er
MECHANICAL PERFORMANCE
TESTING NOTES
Springs were fatigue tested at 4 hz in a cantilevered loading.
You have the responsibility to conduct full-scale end-product performance testing
to determine suitability in your application, and you assume all risk and liability arising from your use of the information and/or use or handling of any product.
https://www.avient.com/sites/default/files/2020-08/specialty-dispersions-overview.pdf
Each batch is developed and
tested in house so you can rely on lot-to-
lot consistency with tight color tolerances.
You have the responsibility to conduct full-scale end-product performance testing
to determine suitability in your application, and you assume all risk and liability arising from your use of the information and/or use or handling of any product.
You have the responsibility to conduct full-scale end-product performance testing
to determine suitability in your application, and you assume all risk and liability arising from your use of the information and/or use or handling of any product.
https://www.avient.com/sites/default/files/2023-10/LubriOne Product Selection Guide.pdf
LUBRIONE™
INTERNALLY LUBRICATED
FORMULATIONS
PRODUCT SELECTION GUIDE
PRODUCT DESCRIPTION UNITS
TEST
METHOD
NN–000/15T
BLACK
NN–20GF–
10GB/13T–2S
BLACK
NN–30GF/10T
WHITE
LB8900-0001
30GF/15T
NATURAL
LB8900-0002
30GF/13T-2S
NATURAL
LB8900-0003
18T-2S
NATURAL
ATT–000/5T
BLACK
AT–000/18T–
2S NATURAL
5209 FPL 20
NATURAL
PS–30GF/2S
NATURAL
LB5210–0237
1B NATURAL
PC–10CF/15T
BLACK
Base Polymer PA 66 PA 66 PA 66 PK PK PK POM POM POM PBT PP PC
General Properties
Specific Gravity g/cm3 ASTM D792 1.23 1.46 1.47 1.56 1.55 1.33 1.38 1.47 1.51 1.54 1.13 1.31
Molding Shrinkage ASTM D955
Flow % 1.0–2.0 0.20–0.50 0.50–1.0 0.30–0.60 0.20–0.40 1.7–2.3 1.5–2.0 2.0–3.0 2.0–3.0 0.20–0.40 0.10–0.30 0.10–0.30
Water Absoprtion (23°C, 24 hr.) % ASTM D570 0.8 – 0.050–1.0 0.3 0.4 0.4 0.050 – 0.050 – – –
Mechanical Properties
Tensile Modulus(1) MPa ASTM D638 2650 9650 9790 8050 7380 1250 965 1770 2420 8620 4140 –
Tensile Strength(1) (Yield) MPa ASTM D638 61.4 119 122 119 94 47 35 40 45 108 72.4 90
Tensile Elongation(1) (Break) % ASTM D638 3.0–5.0 1.0–3.0 1.5 3 2 35 40 30 26 3 – –
Flexural Modulus MPa ASTM D790 2760 6890 6890 7380 6410 1300 1080 1740 1790 6690 4840 5500
Flexural Strength MPa ASTM D790 108 172 214 182 167 55 41.4 62.7 68.3 165 110 130
Coefficient of Friction ASTM D1894
vs.
Steel – Static 0.25 0.46 0.18 0.15 0.12 0.19 0.11 0.14 0.13 0.24 0.17 0.17
Impact
Notched Izod Impact (23°C,
3.18 mm, Injection Molded)
J/m ASTM D256A 41 64(6) 110 107 107 70 80 37 37 75 – 69
Thermal Properties
Heat Deflection Temperature ASTM D648
0.45 MPa °C 215(6) – 250 215 216 184 152 151(6) 153(6) 218(6) – –
1.8 MPa °C 65(6) 239(7) 244(6) 210 210 75 94 81.1(6) 88 197(6) – 135(5)
Electrical Properties
Surface Resistivity ohms/sq ASTM D254 – – – 1.30x1012 1.9x1012 5.2x1012 – – – – – 1.0x109
Dielectric Strength (Short Time) kV/mm – – 8.5 – – – – – – – – –
Flammability
Flame Rating Class UL 94 HB – – HB HB HB – HB – – – –
LubriOne™ Internally Lubricated Formulations
NOTES (1) Type I, 5.1mm/min
(2) Type I, 21.3 mm/min
(3) Type I, 50 mm/min
(4) Type I, 5.1mm/min, Break
(5) 3.2 mm thick, Unannealed
(6) 6.35 mm thick, Unannealed
(7) 3.2 mm thick, Annealed
PRODUCT DESCRIPTION UNITS
TEST
METHOD
LB6000-
5024 RS HI
Natural
LB6000-
5021 RS S1
Black
LB6000-
5021 RS X2
Black
LB6000-
5019 X1
Black
LB6700-
5001 RS AF
Black
NN-
000/01M
Black SO
REC
LB6600-
5030 RS
Grey
LB3300-
5010 RS
Natural
LB3300-
5005 RS
Natural
REC
LB3220-
5001 RS C
Natural X1
LB8900-
5010 GP
Grey
LB8900-
5006 RS PE
Natural
LB8900-
5004 RS PE
Natural
LB4200-
5022 Black
LB4200-
5023
Natural
Base Polymer PA 6 PA6/PA66 PA66 PBT PC PKE POM
Lubricant UHMWPE1 UHMWPE UHMWPE UHMWPE UHMWPE MoS22 Graphite UHMWPE UHMWPE UHMWPE Graphite UHMWPE UHMWPE MoS2 UHMWPE
Filler type GF10 GF30 GF30 GF50 GF50 Unfilled GF33 GF20 MI20 GF10 Unfilled GF20 GF30 Unfilled Unfilled
General Properties
Specific Gravity g/cm3 ISO 1183 1.18 1.35 1.39 1.55 1.58 1.14 1.44 1.42 1.46 1.23 1.26 1.34 1.43 1.4 1.35
Mechanical Properties
Tensile Modulus (23°C) MPa ISO 527-1 4250 9500 9000 15500 16600 3500 10600 6300 3330 4000 1630 5300 9250 2470 2150
Tensile Strength (Yield, 23°C) MPa ISO-527-2 97 150 160 205 200 85 164 102 55 60 60 108 99.1 55 50
Tensile Elongation (Break, 23°C) % ISO-527-2 12 2.5 3 2.7 2.4 3.4 2.0 4.2 8 2.5 46 3.7 1.5 11 11
Flexural Strength (23°C) MPa ISO 178 103 – – 285 265 108 215 127 78 85 38 155 117 73 68
Flexural Modulus (23°C) MPa ISO 178 3250 – – 12400 11100 2690 9000 4700 3000 3100 1380 4600 5450 2210 2070
Impact
Charpy Notched Impact Strength
(23°C, Injection Molded)
kJ/m^2 ISO 179 14 12 10 15 10 3 6 7.7 4.3 12 15 10 7.6 8 5
Charpy Unnotched Impact
Strength (23°C, Injection Molded)
kJ/m^2 ISO 179 82 55 61 75 60 65 50 47 69 - NB 63 36 NB NB
Thermal Properties
Deflection Temperature Under Load
1.8 Mpa, Unannealed
°C ISO 75-2/A 107 – – 204 – 73 235 – – – 90 210 204 86 80
Cofficient of Friction (CoF) & Wear Rate
CoF vs.
You have the responsibility to conduct full-scale end-product performance testing
to determine suitability in your application, and you assume all risk and liability arising from your use of the information and/or use or handling of any product.
https://www.avient.com/sites/default/files/2023-04/Fiber Colorants and Additives Brochure.pdf
Every subsequent
lot is internally tested in comparison with the
standard and is accompanied by a Quality Control
Report.
Our laboratories are
equipped with quality instrumentation to test all
necessary parameters to ensure the highest quality
product suitable for the application and to fulfill
customer requirements.
You have the responsibility to conduct full-scale end-product performance testing
to determine suitability in your application, and you assume all risk and liability arising from your use of the information and/or use or handling of any product.
https://www.avient.com/sites/default/files/resources/Novel_Thermoplastic_elastomers_for_overmolding_applications.pdf
A schematic diagram of this test procedure is shown in Figure 3.
The testing is
conducted on a molded substrate with a TPE skin insert molded onto it.
Schematic Diagram of the peel test.
https://www.avient.com/sites/default/files/2021-05/renol-ul94-compliant-masterbatches-brochure.pdf
Each one specifies its own fire hazard tests and fail/pass criteria, which depend on the fire
resistance required for the plastic part.
The fire hazard
tests specified in this standard are known as Glow-Wire (GW) tests.
The most common tests specified by UL94 are the vertical burning (V-0; V-1; V-2) test and horizontal
burning (HB) test.
https://www.avient.com/sites/default/files/2021-05/dock-shelter-1-page.pdf
LOADING DOCK
SHELTERS
R E I N F O R C I N G S T A Y S
Replacement for steel or composite stays to provide reliable
seal from external environment:
• Withstand repeated flex and twisting, pass rigorous
proprietary flexural testing requirements
• Maintain performance in extreme temperatures
• Enabled repeated twisting and flexing
without failure, up to 90˚ bends, due to
exceptional mechanical properties
• Customized finishing to meet specific shape
and edge surface requirements
• Improved supply reliability with product
manufactured in Montrose, CO
Gordon Composites™ Thermoset Composite
Springs
KEY REQUIREMENTS
WHY AVIENT?