https://www.avient.com/sites/default/files/2020-12/firecon-cpe-a-processing-guide-spanish-1.pdf
Precauciones: el extrusor no se debe dejar en reposo con el material en el barril caliente.
Processing conditions can cause material properties to shift from the values stated in the information.
Processing conditions can cause material properties to shift from the values stated in the information.
https://www.avient.com/sites/default/files/2020-07/sem-w-c-solutions-for-optical-fiber-cable-product-bulletin-a4.pdf
ECCOH™ LSFOH 6153/6154 UV Formulations
Improved processing speeds & greater gel resistance for
optical fiber cables
ECCOH™ LSFOH 6153 UV and 6154 UV grades are
low smoke, fume, non-halogen material solutions
for optical fiber cables with increased processing
speeds and greater resistance to chemicals such
as gel water blocking compounds, used to protect
optical fibers.
They also enable lower wall thickness, reducing
raw material used in production.
Processing conditions can cause material properties to shift from the values stated in the information.
https://www.avient.com/sites/default/files/2024-04/LubriOne Internally Lubricated Formulations PTFE Free Series Product Bulletin.pdf
These materials
combine the unique benefits of various internal
lubricants with a wide array of base engineering
resins.
KEY CHARACTERISTICS
• Excellent wear resistance
• Reduced friction, heat build-up, noise
& vibration
• Improved processability & surface finish
on parts
• Lower power requirements & low
maintenance
• Reduced tool contamination and corrosion
• Reduction in lubricant migration time
• Design flexibility
• Reduced weight
• Chemically resistant
MARKETS & APPLICATIONS
Ideal for applications in many industries including
transportation, industrial, household, electrical
and electronics including:
• Transportation – Fuel flap axis, interior door
handle axis, gears, seat mechanics, sun-roof
sliding mechanisms, side mirror parts
• Industrial – Conveyor belt gears, pulleys
• Household – Window/door runners, furniture
parts, hinges
• Electrical and electronics – Electrical plug
safety parts, printers, barcode scanners
PRODUCT BULLETIN
EUROPE GRADES
ASIA GRADES
Material Name Base Resin Reinforcing Filler Lubricating Filler
LubriOne LB6000-5024 RS HI natural
PA6
GF10 UHMWPE
Lubrione LB6000-5021 RS S1 GF30 UHMWPE
Lubrione LB6000-5021 RS X2 GF30 UHMWPE
LubriOne LB6000-5019 X1 black GF50 UHMWPE
LubriOne LB6700-5001 RS AF black PA6/PA66 GF50 UHMWPE
LubriOne NN-000/01M black SO
PA66
Unfilled MoS2
LubriOne REC LB6600-5030 RS grey GF33 Graphite
LubriOne LB3300-5010 RS natural
PBT
GF20 UHMWPE
LubriOne LB3300-5005 RS natural MI20 UHMWPE
LubriOne REC LB3220-5001 RS C natural X1 PC GF10 UHMWPE
LubriOne LB8900-5010 GP grey
PKE
Unfilled Graphite
LubriOne LB8900-5006 RS PE natural GF20 UHMWPE
LubriOne LB8900-5004 RS PE natural GF30 UHMWPE
LubriOne LB4200-5022 black
POM
Unfilled MoS2
LubriOne LB4200-5023 natural Unfilled UHMWPE
LubriOne LB9200-5012 RS PE natural PPS GF30 UHMWPE
Material Name Base Resin Reinforcing Filler Lubricating Filler
LubriOne LB6600-8056 LB BK001
PA66
Unfilled LDPE
LubriOne LB6600-8054 RS BK001 CF30 LDPE
LubriOne LB6600-8052 RS BK001 GF30 LDPE
LubriOne LB4200-8032 RS NC001
POM
GF30 LDPE
LubriOne LB4200-8030 AR NC001 AF10 LDPE
LubriOne LB4200-8026 LB BK001 Unfilled LDPE+HDPE
LubriOne LB3200-8022 LB BK001
PC
Unfilled UHMWHDPE
LubriOne LB3200-8021 RS BK001 GF30 UHMWHDPE
LubriOne LB7600-8008 RS BK001 PPO GF20 UHMWHDPE
Copyright © 2024, Avient Corporation.
Processing conditions can cause material properties to shift from the values stated in the information.
https://www.avient.com/sites/default/files/2023-01/Mevopur Healthcare Colorants and Formulations Special Effects Application Bulletin_0.pdf
However, these raw
materials often lack the regulatory documentation
to support their use in healthcare applications.
Processing conditions can cause material properties to shift from the values stated in the information.
It is the responsibility of the medical device manufacturer and the person placing the medical device on the market to ensure compliance of the medical device with all applicable laws and regulations, including
the suitability of all raw materials and components used for its manufacture.
https://www.avient.com/sites/default/files/2022-12/Mevopur Healthcare Functional Additives Medical Devices Application Bulletin.pdf
KEY CHARACTERISTICS
• Manufactured at four ISO 13485 certified sites,
providing global consistency and increased
security of supply
• Documented change control beyond CAS
number reducing risk of change
• Non-phthalate and formulated without animal-
derived substances
• Available for use in a wide range of polymers
including polyolefins, styrenics, polycarbonate
and alloys, polyester, POM
• Functionality can be combined with colorants
into convenient combination concentrates and
ready-to-use formulations
REGULATORY SUPPORT
• Raw materials tested to:
- ISO 10993-1 and USP biological
evaluation
- European Pharmacopeia 3.1.3/3.1.5
(polyolefin)
- USP (polyethylene)
- ICH Q3D elemental impurities
• Registered Drug Master File (Type III) and/or
Device Master File
• Food contact established with FDA/EU*
APPLICATION BULLETIN
* FDA/EU compliance information available upon request
FUNCTIONALITY TARGET APPLICATIONS
DRUG
DELIVERY
DEVICES
SYRINGES &
NEEDLES DIAGNOSTICS CATHETERS
Clarifying PP
Sorbitol-free for transparent
applications with reduced migration
and improved thermal stability
Lubricant—
permanent/
non-migrating
Fast acting reduction in friction
for wide variety of polymers such
as PP, ABS, POM, PC
Protection from
UV in transparent
applications for PP,
PE, PETG, COP
UV blocking in 290-450nm with
no impact on clarity; can be
combined with colors (e.g., amber)
Antistatic ready-to-
use solution for PP,
ABS, PC/ABS
Permanent/non-migrating;
fast decay time independent
of % relative humidity
Gamma/e-beam
sterilization
protection of the
polymer
Preserving the properties of
PP and COC/COP; reduction
in yellowing using Color
Compensation Technology (CCT)
Reduced material
consumption/cycle
time—nucleation
Fast acting new generation
nucleant for PE and PP; improved
thermal and mechanical properties
allows wall thinning; reduction of
tolerance/dimensional problems
between different colors
Laser marking
replacing ink
printing/labels
Solvent-free, high-speed
identification for Nd/YAG laser
for PE,PP, ABS, PC, POM
Antioxidants for
PE, PP, TPE
Thermal protection during
converting/downstream sterilization
Brand protection/
anticounterfeit Covert and non-covert systems
Healthcare use limitations apply—see below.
Processing conditions can cause material properties to shift from the values stated in the information.
It is the responsibility of the medical device manufacturer and the person placing the medical device on the market to ensure compliance of the medical device with all applicable laws and regulations, including
the suitability of all raw materials and components used for its manufacture.
https://www.avient.com/sites/default/files/2022-12/Mevopur Healthcare Functional Additives Pharma Pkg Application Bulletin.pdf
Reduction in yellowing using
Color Compensation Technology (CCT)
Reduced material
consumption/cycle
time/improved
properties—nucleation
Fast acting new generation
nucleant for PE and PP; improved
dimensional stability, thermal
and mechanical properties
Laser marking replacing
ink printing/labels
Solvent-free, high-speed identification
for Nd/YAG laser
Antiblock for
PE/PP film
Non-migrating additive system
maintaining high gloss and printability
Antioxidants for
PE, PP, TPE
Thermal protection during converting/
downstream sterilization
Brand protection/
anticounterfeit Range of covert and non-covert systems
Volatiles/odor absorber
for PE/PP
Physical absorption of a wide range
of molecules responsible for odor,
VOC and potential extractables/
leachables in plastics
Healthcare use limitations apply—see below.
Processing conditions can cause material properties to shift from the values stated in the information.
It is the responsibility of the medical device manufacturer and the person placing the medical device on the market to ensure compliance of the medical device with all applicable laws and regulations, including
the suitability of all raw materials and components used for its manufacture.
https://www.avient.com/sites/default/files/2024-12/Complet PKE Product Bulletin.pdf
These materials
are semi-crystalline and deliver excellent chemical
resistance, low moisture uptake, and dimensional
stability similar to nylon (PA6 and PA66).
KEY CHARACTERISTICS
• Chemical resistance
• Maintaining high impact performance at low
temperatures
• Low moisture uptake
• Dimensional stability comparable to nylon
• Higher impact resistance than short fiber
alternatives
• Eco-conscious alternative to nylons
• More cost-effective solution than specialty
nylons
• Available in non-PFAS* formulations to achieve
UL 94 V-0 flame rating at 1.5 mm
MARKETS & APPLICATIONS
These materials are for use in applications
traditionally made of metal requiring moisture,
chemical and cold impact performance
requirements, including:
• Industrial – pipes, tubing, fluid management
• Electrical & Electronics – connectors,
battery components, battery housings
• Transportation – under-the-hood fuel/
chemical contact components, non-structural
interior components
• Oil & Gas – fuel pump components, fuel doors
PRODUCT BULLETIN
* Non-PFAS flame-retardant (FR) grades are manufactured without
intentionally added PFAS-based raw materials.
Processing conditions can cause material properties to shift from the values stated in the information.
https://www.avient.com/sites/default/files/2022-01/Bergamid Laser Welding Solutions Product Bulletin.pdf
The materials used for laser welding must allow
a minimum 20% transmission rate for laser energy.
To further support customers, Avient offers a range
of value-added services and is ready to collaborate
on part design, material compatibility evaluations,
laser welding process selection and more to drive
success.
Processing conditions can cause material properties to shift from the values stated in the information.
https://www.avient.com/sites/default/files/2020-08/edgetek-3d-lds-product-bulletin.pdf
The new Edgetek materials solutions can be
wildly applied in a range of key industries including
5G base stations, medical devices, consumer
electronics and more.
The material solutions offer high
design flexibility, multi-function integration, size
miniaturization and weight reduction to meet
demanding manufacturing requirements without
compromising production efficiency and cost.
Processing conditions can cause material properties to shift from the values stated in the information.
https://www.avient.com/sites/default/files/2024-02/US_OH_North Baltimore_ ISO_IEC 17025.pdf
No. 0562.01) Revised 05/31/2022 Page 1 of 1
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
AVIENT CORPORATION
733 East Water Street
North Baltimore, OH 45872
Claire Holman Phone: (419) 257-1327
MECHANICAL
Valid To: October 31, 2023 Certificate Number: 0562.01
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this
laboratory to perform the following automotive plastics tests:
Test Method: Test Name:
ASTM D412 Tensile
ASTM D523 Specular Gloss
ASTM D618 (A) Conditioning of Plastics
ASTM D624 (Die C) Tear Strength
ASTM D638 Tensile Properties
ASTM D792 (A) Density and Specific Gravity by Displacement
ASTM D1004 Initial Tear Resistance
ASTM D1203 (A) Volatile Loss
ASTM D1895 (A) Apparent Density, Bulk Factor, Pourability
ASTM D1921 Particle Size (Sieve Analysis)
ASTM D2240 Durometer Hardness (Shore A and D)
ASTM E1331 Color by Spectrophotometry Using Hemispherical Geometry
FMVSS 571.302 Flammability
FORD BN-102-01 (A) Low Temperature Flexibility
FORD BO-131-03 Interior Odor
ISO 3795 Determination of Burning Behavior of Interior Materials
SAE J323 (A) Cold Cracking (Mandrel Bend)
SAE J1351 Hot Odor for Insulation Materials
SAE J1545 Instrumental Color Difference Measurement
SAE J1756 Fogging Characteristics of Interior Automotive Materials (Photometric Only)
DOC-058151 Angle of Repose
1 Laboratory Developed Method
For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.